In the present study, pool boiling heat transfer coefficients of LiBr solution were obtained for smooth, corrugated, floral and low fin tubes. Test range covered saturation pressure from 7.38 kPa to 101.3 kPa, LiBr concentration from 0% to 50%. Low fin tube yielded the highest heat transfer coefficient followed by floral, corrugated and smooth tube. The sequence was the same independent of saturation pressure or LiBr concentration. For the low fin tube, the heat transfer enhancement ratio ranged from 1.34 to 2.37. Those of floral tube are 1.16 to 1.64 and those of corrugated tube are 0.90 to 1.43. The enhancement ratio decreased as LiBr concentration increased. No general trend is observed for the effect of saturation pressure. Exceptionally high heat transfer coefficient was obtained for the low fin tube in pure water. The reason may be attributed to many small bubbles at high frequency due to the existence of low fins. Boiling heat transfer correlations were developed which are applicable for saturation pressure from 7.38 kPa to 101.3 kPa and LiBr concentration from 0% to 50%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.