SummaryBackground-Metformin might reduce insulin requirement and improve glycaemia in patients with type 1 diabetes, but whether it has cardiovascular benefits is unknown. We aimed to investigate whether metformin treatment (added to titrated insulin therapy) reduced atherosclerosis, as measured by progression of common carotid artery intima-media thickness (cIMT), in adults with type 1 diabetes at increased risk for cardiovascular disease.
AimHypoglycaemia in Type 1 diabetes is associated with mortality and morbidity, especially where awareness of hypoglycaemia is impaired. Clinical pathways for access to continuous glucose monitoring (CGM) and flash glucose monitoring technologies are unclear. We assessed the impact of CGM and flash glucose monitoring in a high‐risk group of people with Type 1 diabetes.MethodsA randomized, non‐masked parallel group study was undertaken. Adults with Type 1 diabetes using a multiple‐dose insulin‐injection regimen with a Gold score of ≥ 4 or recent severe hypoglycaemia were recruited. Following 2 weeks of blinded CGM, they were randomly assigned to CGM (Dexcom G5) or flash glucose monitoring (Abbott Freestyle Libre) for 8 weeks. The primary outcome was the difference in time spent in hypoglycaemia (below 3.3 mmol/l) from baseline to endpoint with CGM versus flash glucose monitoring.ResultsSome 40 participants were randomized to CGM (n = 20) or flash glucose monitoring (n = 20). The participants (24 men, 16 women) had a median (IQR) age of 49.6 (37.5–63.5) years, duration of diabetes of 30.0 (21.0–36.5) years and HbA1c of 56 (48–63) mmol/mol [7.3 (6.5–7.8)%]. The baseline median percentage time < 3.3 mmol/l was 4.5% in the CGM group and 6.7% in the flash glucose monitoring. At the end‐point the percentage time < 3.3 mmol/l was 2.4%, and 6.8% respectively (median between group difference −4.3%, P = 0.006). Time spent in hypoglycaemia at all thresholds, and hypoglycaemia fear, were different between groups, favouring CGM.Conclusion
CGM more effectively reduces time spent in hypoglycaemia in people with Type 1 diabetes and impaired awareness of hypoglycaemia compared with flash glucose monitoring. (Clinical Trial Registry No: NCT03028220)
Background: The I HART CGM study showed that real-time continuous glucose monitoring (RT-CGM) has greater beneficial impact on hypoglycemia than intermittent flash glucose monitoring (flash) in adults with type 1 diabetes (T1D) at high risk. The impact of continuing RT-CGM or switching from flash to RT-CGM for another 8 weeks was then evaluated.Methods: Prospective randomized parallel group study with an extension phase. After a 2-week run-in with blinded CGM, participants were randomized to either RT-CGM or flash for 8 weeks. All participants were then given the option to continue with RT-CGM for another 8 weeks. Glycemic outcomes at 8 weeks are compared with the 16-week endpoint.Results: Forty adults with T1D on intensified multiple daily insulin injections and with impaired awareness of hypoglycemia or a recent episode of severe hypoglycemia were included (40% female, median [IQR] age 49.5 [37.5–63.5] years, diabetes duration 30.0 [21.0–36.5] years, HbA1c 56 [48–63] mmol/mol, and Gold Score 5 [4–5]), of whom 36 completed the final 16-week extension. There was a significant reduction in percentage time in hypoglycemia (<3.0 mmol/L) in the group switching from flash to RT-CGM (from 5.0 [3.7–8.6]% to 0.8 [0.4–1.9]%, P = 0.0001), whereas no change was observed in the RT-CGM group continuing with the additional 8 weeks of RT-CGM (1.3 [0.4–2.8] vs. 1.3 [0.8–2.5], P = 0.82). Time in target (3.9–10 mmol/L) increased in the flash group after switching to RT-CGM (60.0 [54.5–67.8] vs. 67.4 [56.3–72.4], P = 0.02) and remained the same in the RT-CGM group that continued with RT-CGM (65.9 [54.1–74.8] vs. 64.9 [49.2–73.9], P = 0.64).Conclusions: Our data suggest that switching from flash to RT-CGM has a significant beneficial impact on hypoglycemia outcomes and that continued use of RT-CGM maintains hypoglycemia risk benefit in this high-risk population.
Although subcutaneously implanted continuous glucose monitoring (CGM) devices have been shown to support diabetes self-management, their uptake remains low due to high costs and poor accuracy and precision arising from their invasiveness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.