Flow rate at the 1-week postoperative visit was the most important predictor of RCAVF patency. Thus, it should be possible to identify patients who would benefit from early intervention or closer follow-up as soon as the first postoperative visit. This should help reduce the use of bridging hemodialysis catheters and minimize the risks of catheter dependency.
PurposeWe report the first use of a sterile elastic exsanguination tourniquet (SET) in performing hemodialysis vascular access procedures in 27 patients. The main advantages of this tourniquet are the reduction of blood loss and need for possible transfusions. Additional benefits are the near-perfect exsanguination and excellent exposure of the operative field.MethodsThis SET is a sterile elastic stockinet device that rolls up the arm starting from the hand by pulling on two handles. The elastic silicone ring provides sufficient pressure (220 ± 30 mmHg) to block arterial flow into the limb. The stockinet can be cut to provide access to the incision area while providing an additional sterile cover over the rest of the limb.ResultsNo transfusions were required in any patients. Minor adverse effects occurred in four patients, including a twisted vessel, a bleeding vascular branch, a tear in atrophic arm skin, and pain, all of which had resolved on subsequent follow-up. Operational recommendations to avoid these adverse effects are outlined.ConclusionsWe conclude that this sterile elastic exsanguination tourniquet is effective and safe in preventing bleeding during upper extremity hemodialysis vascular access procedures.
We reviewed the effectiveness of a gelatin-coated polytetrafluoroethylene (PTFE) graft designed to reduce suture line bleeding and graft weeping. Twenty-nine adults with end-stage renal disease underwent implantation the graft (n = 30) in the arm. All had preoperative ultrasound vascular mapping to assess their options for an autogenous arteriovenous fistula and patients with a history of prior central venous devices or sternotomy underwent contrast venography. A 4- to 7-mm tapered graft (n = 10) was used if the inflow artery was <4.0 mm in diameter, and a 6-mm straight graft (n = 20) was used if the artery was ≥4.0 mm. Intraoperative volume flows were measured by duplex methodology. Precautions to prevent ultrafiltration and seroma development were taken. Eleven clinically significant seromas were detected in 30 sealed PTFE grafts (36.7%), 10 in the 6-mm grafts (50%), and 1 in a 4- to 7-mm graft (10%), a significant difference between graft types. There were no significant differences in flow between the graft types and between grafts with seromas versus no seromas. Five grafts were explanted and one was ligated, resulting in cannulation delays from 2 to 4 months. We conclude that the gelatin-sealed PTFE vascular graft is not the ideal prosthesis for hemodialysis access.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.