BACKGROUND The standard management of autoimmune hepatitis (AIH) is based on corticosteroids, alone or in combination with azathioprine. Second-line treatments are needed for patients who have refractory disease. However, high-quality data on the alternative management of AIH are scarce. AIM To evaluate the efficacy and safety of tacrolimus and mycophenolate mofetil (MMF) and the quality of evidence by using the Grading of Recommendations Assessment, Development and Evaluation approach (GRADE). METHODS A systematic review and meta-analysis of the available data were performed. We calculated pooled event rates for three outcome measures: Biochemical remission, adverse events, and mortality, with their corresponding 95% confidence intervals (CI). RESULTS The pooled biochemical remission rate was 68.9% (95%CI: 60.4-76.2) for tacrolimus, and 59.6% (95%CI: 54.8-64.2) for MMF, and rates of adverse events were 25.5% (95%CI: 12.4-45.3) for tacrolimus and 24.1% (95%CI: 15.4-35.7) for MMF. The pooled mortality rate was estimated at 11.5% (95%CI: 7.1-18.1) for tacrolimus and 9.01% (95%CI: 6.2-12.8) for MMF. Pooled biochemical remission rates for tacrolimus and MMF in patients with intolerance to standard therapy were 56.6% (CI: 43.4-56.6) vs 73.5% (CI: 58.1-84.7), and among non-responders were 59.1% (CI: 48.7-68.8) vs 40.8% (CI: 32.3-50.0), respectively. Moreover, the overall quality assessments using GRADE proved to be very low for all our outcomes in both treatment groups. CONCLUSION Tacrolimus and MMF are in practice considered effective for patients with AIH who are non-responders or intolerant to first-line treatment, but we found no high-quality evidence to support this statement.
Aims The recent 4S-AF (scheme proposed by the 2020 ESC AF guidelines to address stroke risk, symptom severity, severity of AF burden and substrate of AF to provide a structured phenotyping of AF patients in clinical practice to guide therapy and assess prognosis) scheme has been proposed as a structured scheme to characterize patients with atrial fibrillation (AF). We aimed to assess whether the 4S-AF scheme predicts AF progression in patients with self-terminating AF. Methods and results We analysed 341 patients with self-terminating AF included in the well-phenotyped Reappraisal of Atrial Fibrillation: Interaction between HyperCoagulability, Electrical remodelling, and Vascular Destabilization in the Progression of AF (RACE V) study. Patients had continuous monitoring with implantable loop recorders or pacemakers. AF progression was defined as progression to persistent or permanent AF or progression of self-terminating AF with >3% burden increase. Progression of AF was observed in 42 patients (12.3%, 5.9% per year). Patients were given a score based on the components of the 4S-AF scheme. Mean age was 65 [interquartile range (IQR) 58–71] years, 149 (44%) were women, 103 (49%) had heart failure, 276 (81%) had hypertension, and 38 (11%) had coronary artery disease. Median CHA2DS2-VASc (the CHA2DS2–VASc score assesses thromboembolic risk. C, congestive heart failure/left ventricular dysfunction; H, hypertension; A2, age ≥ 75 years; D, diabetes mellitus; S2, stroke/transient ischaemic attack/systemic embolism; V, vascular disease; A, age 65–74 years; Sc, sex category (female sex)) score was 2 (IQR 2–3), and median follow-up was 2.1 (1.5–2.6) years. The average score of the 4S-AF scheme was 4.6 ± 1.4. The score points from the 4S-AF scheme did not predict the risk of AF progression [odds ratio (OR) 1.1 95% CI 0.88–1.41, C-statistic 0.53]. However, excluding the symptoms domain, resulting in the 3S-AF (4S-AF scheme without the domain symptom severity, only including stroke risk, severity of AF burden and substrate of AF) scheme, predicted the risk of progression (OR 1.59 95% CI 1.15–2.27, C-statistic 0.62) even after adjusting for sex and age. Conclusions In self-terminating AF patients, the 4S-AF scheme does not predict AF progression. The 3S-AF scheme, excluding the symptom domain, may be a more appropriate score to predict AF progression. Trial registration numbers Clinicaltrials.gov NCT02726698 for RACE V
ObjectivesPulmonary vein isolation (PVI) is widely accepted as an effective and safe treatment for symptomatic atrial fibrillation (AF). However, data on sex-related differences and associations with clinical outcome and safety of PVI with cryoballoon ablation are limited. We sought to compare sexrelated efficacy and safety of cryoballoon ablation and identify sex-related associations with clinical outcomes.Methods and resultsWe included 650 consecutive patients with AF undergoing PVI with cryoballoon ablation at our institution between 2013 and 2017. The efficacy outcome was the first documented recurrence (>30 s) of AF, atrial flutter or atrial tachycardia (AF/AT) or repeat ablation during follow-up, after a 90-day blanking period. The safety outcome was the incidence of periprocedural complications. Mean age of the population was 58±10, and 210 (32.3%) patients were women. Women were older, had a higher body mass index, had more renal dysfunction and less coronary artery disease as compared with men. The rate of AF/AT recurrence was similar between women and men at 12-month follow-up (27.6% vs 24.8%, p=0.445). The incidence of periprocedural complications was higher in women (12.9% vs 4.6%; p<0.001), specifically groin haematomas and phrenic nerve palsy. On multivariate analysis, left atrial volume index (adjusted OR 1.05, 95% CI 1.00 to 1.10; p=0.032) was associated with the incidence of procedural complications in women. For men, no relation with complications could be found.ConclusionThe efficacy of cryoballoon ablation was similar between women and men; however, women had a higher risk of procedural complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.