This paper describes a structural analysis of the CAD model three versions fixators Sarafix which to explore the possibility of introducing composite materials in the construction of the connecting rod fixators comparing values of displacement and stiffness at characteristic points structure. Namely, we investigated constructional performance of fixators Sarafix with a connecting rod formed from three different composite materials, the same matrix (epoxy resin) with three different types of fibers (E glass, kevlar 49 and carbon M55J). Results of structural analysis fixators Sarafix with a connecting rod made of composite materials are compared with the results of tubular connecting rod fixators made of stainless steel. After comparing the results, from the aspect of stiffness, we gave the final considerations about composite material which provides an adequate substitution for the existing material.
This study investigated the correlation between bone characteristics, the design of orthodontic mini-implants, the pull-out force, and primary stability. This experimental in vitro study has examined commercial orthodontic mini-implants of different sizes and designs, produced by two manufacturers: Tomas-pin SD (Dentaurum, Ispringen, Germany) and Perfect Anchor (Hubit, Seoul, Korea). The total number of 40 mini-implants were tested. There are two properties that are common to all tested implants—one is the material of which they are made (titanium alloy Ti-6Al-4V), and the other is the method of their insertion. The main difference between the mini-implants, which is why they have been selected as the subject of research in the first place, is reflected in their geometry or design. Regardless of the type of implant, the average pull-out forces were found to be higher for a cortical bone thickness (CBTC) of 0.62–0.67 mm on average, compared to the CBTC < 0.62 mm, where the measured force averages were found to be lower. The analysis of variance tested the impact of the mini-implant geometry on the pull-out force and proved that there is a statistically significant impact (p < 0.015) of all three analyzed geometric factors on the pull-out force of the implant. The design of the mini-implant affects its primary stability. The design of the mini-implant affects the pulling force. The bone quality at the implant insertion point is important for primary stability; thus, the increase in the cortical bone thickness increases the value of the pulling force significantly.
The development process of the knowledge-based engineering (KBE) system for the structural size optimization of external fixation device is presented in this paper. The system is based on algorithms for generative modeling, finite element model (FEM) analysis, and size optimization. All these algorithms are integrated into the CAD/CAM/CAE system CATIA. The initial CAD/FEM model of external fixation device is verified using experimental verification on the real design. Experimental testing is done for axial pressure. Axial stress and displacements are measured using tensometric analysis equipment. The proximal bone segment displacements were monitored by a displacement transducer, while the loading was controlled by a force transducer. Iterative hybrid optimization algorithm is developed by integration of global algorithm, based on the simulated annealing (SA) method and a local algorithm based on the conjugate gradient (CG) method. The cost function of size optimization is the minimization of the design volume. Constrains are given in a form of clinical interfragmentary displacement constrains, at the point of fracture and maximum allowed stresses for the material of the external fixation device. Optimization variables are chosen as design parameters of the external fixation device. The optimized model of external fixation device has smaller mass, better stress distribution, and smaller interfragmentary displacement, in correlation with the initial model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.