2012
DOI: 10.2507/23rd.daaam.proceedings.132
|View full text |Cite
|
Sign up to set email alerts
|

Research of Influential Constructional Parameters on the Stability of the Fixator Sarafix

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…FEM analysis showed that the maximum displacement at the fracture site is located at the upper segment of the bone model, ie at the very end of the segment and it is 3.34 mm, while the maximum displacement value at the structure is at the ends of the fixation wedges and is 2.68 mm, which is within the permissible displacements for this type of construction. Studies [9,18] also showed similar displacement values for a similar configuration of the external fixation device loaded with the same load case.…”
Section: Discussionmentioning
confidence: 67%
See 2 more Smart Citations
“…FEM analysis showed that the maximum displacement at the fracture site is located at the upper segment of the bone model, ie at the very end of the segment and it is 3.34 mm, while the maximum displacement value at the structure is at the ends of the fixation wedges and is 2.68 mm, which is within the permissible displacements for this type of construction. Studies [9,18] also showed similar displacement values for a similar configuration of the external fixation device loaded with the same load case.…”
Section: Discussionmentioning
confidence: 67%
“…Studies [9,27] also showed similar stiffness values for a similar configuration of the external fixation device loaded with the same load case.…”
Section: Discussionmentioning
confidence: 69%
See 1 more Smart Citation
“…Values of stiffness are also in the range of allowed values for this type of design. Studies [10,20] also showed similar stiffness values for a similar configuration of the external fixation device loaded with the same load case.…”
Section: Discussionmentioning
confidence: 69%
“…In recent period, conducted researches are not only based on experimental investigations, but also on benefits of 3D modeling and numerical analysis. This way, a more complete image and understanding of fixation device behavior is obtained [10,11,12].…”
Section: Introductionmentioning
confidence: 99%