BackgroundWork-related injuries are the most important cause of work absence, disability, retirement, mutilation, and even mortality. In Iran a great number of work-related injuries are occurred in construction industry. However, less than 12% of total workers are active in the construction sector.ObjectivesThis study aimed to determine the incidence rate of work-related injuries, the type of injuries, and its other determinants among the construction workers of Ilam (Iran).Patients and MethodsThe participants were the workers and staffs working in the construction activities of Ilam in Western Iran. All the recorded injuries and deaths related to the construction workers of Ilam from 2006-2009 were collected from the Bureau of Labor and Social Affairs and then analyzed by the statistical package of SPSS (version 19, for Windows).ResultsDuring 2006 - 2009 in Ilam, 387workers encountered the building accidents. Their mean age was 34.3 years (SD = 12.4). The average annual incidence of work-related injuries among the workers was 8.2 per 1000 workers. Fracture with 275 cases (71%) was the most common outcome of injuries, and slipping and falling with 77 cases (36%) were the most important events and exposures. The most important factor related to injuries was the lack of surveillance by employers which was also related with the severity of accident-induced injuries (P < 0.004).ConclusionsConsidering the effectiveness of the relevant preventive measures activities such as training the workers as well as using safety tools and more surveillance by employers can decrease the number of work-related injuries among constructive workers.
BackgroundBuilding materials and the ventilation rate of a building are two main factors influencing indoor radon and thoron levels (two radioactive gases which have the most important role in human natural radiation exposure within dwellings).ObjectivesThis analytical descriptive study was intended to determine the relationship between indoor radon and thoron concentrations and the building materials used in interior surfaces, as well as between those concentrations and the type of ventilation system (natural or artificial).Materials and Methods102 measurements of radon and thoron levels were taken from different parts of three hospital buildings in the city of Kermanshah in the west of Iran, using an RTM-1688-2 radon meter. Information on the type of building material and ventilation system in the measurement location was collected and then analyzed using Stata 8 software and multivariate linear regression.ResultsIn terms of radon and thoron emissions, travertine and plaster were found to be the most appropriate and inappropriate covering for walls, respectively. Furthermore, granite and travertine were discovered to be inappropriate materials for flooring, while plastic floor covering was found suitable. Natural ventilation performed better for radon, while artificial ventilation worked better for thoron.ConclusionsInternal building materials and ventilation type affect indoor radon and thoron concentrations. Therefore, the use of proper materials and adequate ventilation can reduce the potential human exposure to radon and thoron. This is of utmost importance, particularly in buildings with a high density of residents, including hospitals.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.