SummaryBackgroundMagnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue.MethodsWe recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed.Findings284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72–86]) and presence (97% [91–99]) were significantly greater than that of ultrasound (70% [62–78] for disease extent, 92% [84–96] for disease presence); a 10% (95% CI 1–18; p=0·027) difference for extent, and 5% (1–9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85–98]) was significantly greater than that of ultrasound (81% [64–91]); a difference of 14% (1–27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86–99) with MRE and 84% (65–94) with ultrasound (difference 12% [0–25]; p=0·054). There were no serious adverse events.InterpretationBoth MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly.FundingNational Institute of Health and Research Health Technology Assessment.
The majority of patients with a permanent colostomy develop a parastomal hernia within the first two post-operative years. Parastomal herniation appears unlikely to develop with an abdominal wall defect diameter ≤25 mm provided this does not enlarge with time. Surgical techniques that utilise stapling devices to form a 'custom-made' and rigid trephine might reduce the herniation risk.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.