CONSPECTUS The successful development of a noninvasive blood glucose sensor that can operate reliably over sustained periods of time has been a much sought after but elusive goal in diabetes management. Since diabetes has no well-established cure, control of elevated glucose levels is critical for avoiding severe secondary health complications in multiple organs including the retina, kidney and vasculature. While fingerstick testing continues to be the mainstay of blood glucose detection, advances in electrochemical sensing-based minimally invasive approaches have opened the door for alternate methods that would considerably improve the quality of life for people with diabetes. In the quest for better sensing approaches, optical technologies have surfaced as attractive candidates as researchers have sought to exploit the endogenous contrast of glucose, notably its absorption, scattering, and polarization properties. Vibrational spectroscopy, especially spontaneous Raman scattering, has exhibited substantial promise due to its exquisite molecular specificity and minimal interference of water in the spectral profiles acquired from the blood-tissue matrix. Yet, it has hitherto been challenging to leverage the Raman scattering signatures of glucose for prediction in all but the most basic studies and under the least demanding conditions. In this Account, we discuss the newly developed array of methodologies that address the key challenges in measuring blood glucose accurately using Raman spectroscopy and unlock new prospects for translation to sustained noninvasive measurements in people with diabetes. Owing to the weak intensity of spontaneous Raman scattering, recent research has focused on enhancement of signals from the blood constituents by designing novel excitation-collection geometries and tissue modulation methods while our attempts have led to the incorporation of nonimaging optical elements. Additionally, invoking mass transfer modeling into chemometric algorithms has not only addressed the physiological lag between the actual blood glucose and the measured interstitial fluid glucose values but also offered a powerful tool for predictive measurements of hypoglycemia. This framework has recently been extended to provide longitudinal tracking of glucose concentration without necessitating extensive a priori concentration information. These findings are advanced by the results of recent glucose tolerance studies in human subjects, which also hint at the need for designing nonlinear calibration models that can account for subject-to-subject variations in skin heterogeneity and hematocrit levels. Together, the emerging evidence underscores the promise of a blood withdrawal-free optical platform—featuring a combination of high-throughput Raman spectroscopic instrumentation and data analysis of subtle variations in spectral expression—for diabetes screening in the clinic and, ultimately, for personalized monitoring.
The brain functions through chemical interactions between many different cell types, including neurons and glia. Acquiring comprehensive information on complex, heterogeneous systems requires multiple analytical tools, each of which have unique chemical specificity and spatial resolution. Multimodal imaging generates complementary chemical information via spatially localized molecular maps, ideally from the same sample, but requires method enhancements that span from data acquisition to interpretation. We devised a protocol for performing matrix-assisted laser desorption/ionization (MALDI)-Fourier transform ion cyclotron resonance-mass spectrometry imaging (MSI), followed by infrared (IR) spectroscopic imaging on the same specimen. Multimodal measurements from the same tissue provide precise spatial alignment between modalities, enabling more advanced image processing such as image fusion and sharpening. Performing MSI first produces higher quality data from each technique compared to performing IR imaging before MSI. The difference is likely due to fixing the tissue section during MALDI matrix removal, thereby preventing analyte degradation occurring during IR imaging from an unfixed specimen. Leveraging the unique capabilities of each modality, we utilized pan sharpening of MS (mass spectrometry) ion images with selected bands from IR spectroscopy and midlevel data fusion. In comparison to sharpening with histological images, pan sharpening can employ a plethora of IR bands, producing sharpened MS images while retaining the fidelity of the initial ion images. Using Laplacian pyramid sharpening, we determine the localization of several lipids present within the hippocampus with high mass accuracy at 5 μm pixel widths. Further, through midlevel data fusion of the imaging data sets combined with k-means clustering, the combined data set discriminates between additional anatomical structures unrecognized by the individual imaging approaches. Significant differences between molecular ion abundances are detected between relevant structures within the hippocampus, such as the CA1 and CA3 regions. Our methodology provides high quality multiplex and multimodal chemical imaging of the same tissue sample, enabling more advanced data processing and analysis routines.
The existence of pH-dependent surface-enhanced Raman scattering (SERS) of p-aminobenzenethiol (PATP) on Ag nanoparticles has been confirmed by numerous studies, but its mechanism still remains to be clarified. Discussion of the mechanism is at a standstill because of the lack of a systematic investigation of the process behind the pH-induced variation of the PATP behavior. Two-dimensional correlation spectroscopy is one of the most powerful and versatile spectral analysis methods for investigating perturbation-induced variations in dynamic data. Herein, we have analyzed the pH-dependent behavior of PATP using a static buffer solution with pH ranging from 3.0 to 2.0. The order of the variations in the different vibrational intensities was carefully investigated based on 2D correlation SERS spectroscopy. These results have demonstrated that the very first step of the pH-response process involves protonation of the amine group. The pH-response mechanism revealed is an important new component to our understanding of the origin of the b2-type bands of PATP.
Microcalcifications are an early mammographic sign of breast cancer and frequent target for stereotactic biopsy. Despite their indisputable value, microcalcifications, particularly of the type II variety that are comprised of calcium hydroxyapatite deposits, remain one of the least understood disease markers. Here we employed Raman spectroscopy to elucidate the relationship between pathogenicity of breast lesions in fresh biopsy cores and composition of type II microcalcifications. Using a chemometric model of chemical-morphological constituents, acquired Raman spectra were translated to characterize chemical makeup of the lesions. We find that increase in carbonate intercalation in the hydroxyapatite lattice can be reliably employed to differentiate benign from malignant lesions, with algorithms based only on carbonate and cytoplasmic protein content exhibiting excellent negative predictive value (93–98%). Our findings highlight the importance of calcium carbonate, an underrated constituent of microcalcifications, as a spectroscopic marker in breast pathology evaluation and pave the way for improved biopsy guidance.
In the past decade, considerable attention has been focused on the measurement of glycemic markers, such as glycated hemoglobin and glycated albumin, that provide retrospective indices of average glucose levels in the bloodstream. While these biomarkers have been regularly used to monitor long-term glucose control in established diabetics, they have also gained traction in diabetic screening. Detection of such glycemic markers is challenging, especially in a point-of-care setting, due to the stringent requirements for sensitivity and robustness. A number of non-separation based measurement strategies were recently proposed, including photonic tools that are well suited to reagent-free marker quantitation. Here, we critically review these methods while focusing on vibrational spectroscopic methods, which offer highly specific molecular fingerprinting capability. We examine the underlying principles and the utility of these approaches as reagentless assays capable of multiplexed detection of glycemic markers and also the challenges in their eventual use in the clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.