PENILAIAN SAFETY INTEGRITY LEVEL IRADIATOR GAMMA KATEGORI-IV PADA KEGAGALAN SISTEM CRANE PENGONTROL SUMBER ZAT RADIOAKTIF. Penelitian penilaian Safety Integrity Level (SIL) telah dilakukan di fasilitas iradiasi kategori-IV pada sistem crane pengontrol pergerakan sumber zat radioaktif Cobalt-60. Tujuan dari penelitian ini adalah untuk menentukan tingkatan SIL pada iradiator gamma kategori-IV pada simulasi kegagalan sistem pergerakan crane sumber zat radioaktif. Safety integrity level merupakan cara untuk menunjukkan tingkat kegagalan yang masih dapat diterima dari fungsi keselamatan tertentu. Metode pendekatan yang digunakan pada penelitian ini adalah metode probabilistic risk assessment (PRA) dan initial protection layer (IPL). Nilai frekuensi risiko terhadap paparan sumber zat radioaktif Cobalt-60 saat instalasi iradiator gamma beroperasi adalah bernilai 1,7 x 10-2 fail/year. Nilai sil dari simulasi kegagalan yang dilakukan adalah SIL-4 dengan nilai frekuensi kegagalan sebesar 7x10-7 dengan mengoptimalkan sistem perlindungan high alarm dan interlock systems. Presentase pengurangan risiko yang didapatkan adalah sebesar 99,99%.
Salah satu sistem yang berperan penting dalam performa mesin berbahan bakar bensin pada motor matic adalah sistem CVT (Continuously Variable Transmission). Roller merupakan sebuah komponen yang terdapat pada transmisi otomatis atau CVT. Pada umumnya roller memiliki massa 8 gr hingga 18 gr. Roller berperan untuk memberi tekanan pada pulley primer berdasarkan gaya sentrifugal. Semakin tinggi putaran mesin maka roller akan semakin menekan pulley primer sehingga membuat v-belt yang tertekan di pulley primer dapat meneruskan putaran mesin ke pulley sekunder. Massa roller berpengaruh terhadap performa mesin yang dihasilkan. Dynamometer merupakan suatu alat yang dapat menguji performa suatu mesin. Pada penelitian ini membahas tentang pengaruh variasi massa roller CVT terhadap karakteristik performa motor matic 110 cc dan 150 cc menggunakan dynamometer. Variasi massa roller yang digunakan adalah variasi massa roller standar, yaitu 13 gr untuk motor matic 110 cc dan 18 gr untuk motor matic 150 cc. Sedangkan untuk variasi lainnya masing-masing adalah 10 gr dan 12 gr. Pengujian dengan dynamometer dilakukan sebanyak 3 kali per sampel. Hasilnya menunjukkan bahwa horse power paling tinggi yang dapat dihasilkan pada motor matic 150 cc adalah 11,6 HP dengan menggunakan variasi roller 10 gr pada putaran mesin 3475 rpm dan yang paling rendah terdapat pada variasi massa roller standar pada motor matic 110 cc dengan horse power 7,6 HP dengan putaran mesin 3210 rpm. Pada pengujian torsi, penggunaan massa roller 10 gr pada motor matic 150 cc menghasilkan torsi yang paling besar yaitu 35,58 Nm pada 1557 rpm dan yang terendah pada penggunaan massa roller standar motor matic 110 cc yaitu 22,46 Nm pada 1868 rpm. Dapat ditarik kesimpulan bahwa penggantian variasi massa roller dengan massa roller yang lebih ringan dapat meningkatkan horse power dan torsi dari motor matic bertransmisi CVT 110 dan 150 cc.
Liquid extraction of Y that containing Dy using bis-2-Ethylhexyl phosphoric acid (D2EHPA) extractant has been conducted. The purpose of this study is to determine the optimum parameter in a separation process that uses membrane emulsion. As the aqueous phase, a mixed solution of Y2O3 and Gd2O3 containing Y 10 g/L and Gd 250 mg/L was used. D2EHPA as extractant or organic phase with a variety of concentration was diluted with kerosene. Emulsifier Span-80 was used to make an emulsion of membrane liquid. The internal phase of the liquid membrane used 0.20–0.50 M nitric acid, and the external phase used 1–5 M nitric acid. The studied parameters were extractant concentration, stirring speed, stirring time, and the ratio of the internal and external phase. X-Ray Fluorescence (XRF) was used for the analysis of Y and Dy. The analysis of Y and Dy used the X-Ray Fluorescence (XRF). The optimization results of the extraction process of Y with emulsion membrane using D2EHPA extractants obtained the following conclusions: the optimum stirring rate was 8500 rpm, the D2EHPA concentration was 4.5% in kerosene, the internal concentration was 0.45 M nitric acid, the external concentration was 4 M nitric acid, the stirring time was 10 min that fixed stirring rate was 500 rpm, and the ratio of internal and external phase was 1:1. This conditions acquired a separation factor (SF) Y-Gd of 7.57.
Ordered pores structure analysis of mesoporous silica materials using a template of poly(ethylene oxyde)-poly(propylene oxide)-poly(ethylene oxide), PEO-PPO-PEO, triblock copolymer or Pluronics in numerous synthesis conditions has been conducted. Two different length of hydrophilic chain of Pluronics, i.e., P123 (EO 20 PO 70 EO 20) and F127 (EO 106 PO 70 EO 106), produced two different fine pore structures, which were basically hexagonal and cubic. A highly ordered pore structure, confirming with many Bragg peaks, was clearly obtained with the lattice parameters in nanometer scale from analyzing the synchrotron small angle X-ray scattering (SAXS) data. Meanwhile, the surface area and pores size of mesoporous silica determined by nitrogen absorption clearly support the analysis of SAXS data, presenting a complete information of pore order characteristics. This paper shows how the synthesis parameters, such as length of hydrophilic chains, silica precursor concentration, Al:Si ratio and synthesis methods, are related to the structure and order of the pores formed. The SAXS patterns show that the pore order increases with increasing concentration of sodium silicate and decreases with longer sonication time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.