The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 +/- 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 +/- 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.
Intrahepatic artery aneuryms are a rare and potentially life-threatening condition. We present the first case in the English literature of multiple intrahepatic artery aneuryms in a patient with Behçet's disease who presented acutely with rupture. The ruptured aneurysm was treated successfully with transcatheter arterial coil embolization-CT and clinical follow-up confirming a good result. We discuss the management dilemma with regard to prophylactic embolization of the numerous other small asymptomatic intrahepatic aneurysms in this same patient.
Percutaneous CT- and ultrasound-guided radiofrequency ablation of renal cell carcinoma (RCC) has been shown to have very promising medium-term results. We present a unique case of recurrent RCC after partial nephrectomy in a patient with a single kidney and impaired renal function. This tumor could not be visualized either with CT or with ultrasound. A combination of magnetic resonance imaging and fluoroscopic guidance was used, to the best of our knowledge for the first time, to ablate the tumor with radiofrequency. The patient was cancer-free and off dialysis at 30-month follow up.
The Günther Tulip vena cava filter is a safe, effective, well-established device for pulmonary embolism prophylaxis. We report a patient in whom there was migration of the filter to the right atrium, 2 weeks after insertion, caused by a technical error during deployment. An attempt to retrieve the filter percutaneously failed, necessitating removal at open-heart surgery. The potential causes of migration are described and the lessons learned from this unusual case are outlined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.