Timber–Concrete Composite (TCC) structure consists of timber joists or beams effectively interconnected to a concrete slab cast on top of the timber members. This type of structures has applications in multi-storey buildings and short-span bridges particularly in developed countries such as America, Canada, Australia and New Zealand. In Malaysia, these timber concrete composite (TCC) fields are extremely uncommon compared to European country. This paper is investigated the TCC deck system as a new slab structure element that could be used in Malaysia. The use of TCC deck system with Malaysian Kempas timber and normal weight concrete is advantageous in providing a lighter structure, more sustainable and possibly a smaller foundation. Therefore the main objective of this research is to study the vibration behavior of kempas timber (natural timber) in timber deck and TCC deck by experimental modal testing. The vibration data results were conducted by modal experimental test. Then the model is verified by finite element using SAP 2000 software. The connector type that used is screw in TCC deck. The size of each deck is 3.6m x 0.8m, the thickness of concrete is 65mm and the timber beam unit with dimension 3.6 x 0.09x0.04 m. The specimens of timber and TCC deck were tested using an electrodynamic shaker. The data were analyzed using ME Scope software to determine the natural frequency and mode shape of the timber and TCC deck system. The modal experimental results for all tests were more than 8 Hz, it accepted since the vibration limitation for timber floor is 8 Hz. The TCC deck frequency due to shaker excitation is higher than only timber deck which means that the TCC improve vibration resistance property compared with only timber deck vibration resistance.
Lightweight composite deck is widely used as floor system due to the advantage of minimum weight as well as to speedy the construction process. There are numerous investigations on the structural behaviour of lightweight composite deck, but its reliability and understanding on dynamic serviceability remain ambiguous. Therefore, this study intents to numerically investigate the dynamic serviceability of lightweight composite deck as floor system. The lightweight composite deck with dimension of 2900 mm span and 900 mm was modelled in STAAD.Pro. The thickness of lightweight composite deck varied from 100 mm to 225 mm. The isotropic equivalent plate model and effective homogenous criterion were adopted for the geometry and material properties. Dynamic serviceability in term of natural frequency and displacement were analysed in corresponds to the thickness of lightweight composite deck. It is noticeable that by increasing the thickness led to the improvement in the natural frequency. In contrast, the displacement become smaller as the thickness become larger. It was identified that only the lightweight composite deck with thickness 200 mm and 225 mm comply the allowable limit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.