Abstract-Electrical energy is indispensable in people's lives for the sake of survival and for life on the work. Society is now very dependent on electric energy because without the existence of electrical energy the community activity will be stalled.The loads used in electric energy operations vary widely. Electrical energy operations are severely disrupted due to unbalanced load and nonlinear loads. Unbalanced load and nonlinear loads used for the operation of electrical energy can be disturbing because they produce non-pure sinusoidal waves. THD_i (harmonics) caused by the unbalance of load and nonlinear load have an impact on electric energy losses and heat on the transformer. THD_i (harmonics) is caused by unbalance of load and nonlinear load Between Phases RN equal to 7.87%, at SN equal to 3.22%, and at TN 2,41%. After the Passive Filter design is installed THD_i between Phases becomes smaller that is at RN becomes 1.82%, SN becomes 0.82%, and in TN becomes 0.57%.THD_i (harmonics) between phases can be decreased by 76% after Passive Filter is installed. Desain Passive filters are very effective at reducing THD_i (harmonics) in buildings such as laboratories that use the load of imbalances and nonlinear loads for lab.For your paper to be published in the conference proceedings, you must use this document as both an instruction set and as a template into which you can type your own text. If your paper does not conform to the required format, you will be asked to fix it. Keyword : Passive Filter Design, THD_i (Harmonics), Lighting, Convenience.I. INTRODUCTION The use of electrical appliances is increasingly a top priority and causes more expensive electrical energy. Electrical equipment used in power systems can affect the distribution of electrical energy. Distribution of electrical energy is affected by the unbalanced load and non-linear loads used by consumers. Unbalanced loads and nonlinear loads cause current and voltage THD_i (harmonics) and they affect electrical energy conditions. The distortion of the current wave and the voltage generated from the imbalance and non-linear load will be formed waves.The form of current and voltage supplied by an electric power system generator that ideal for the consumer is a pure sinusoid wave. THD_i (harmonics) is generated by the unbalance of load and the nonlinear load forms an impure wave and causes heat to the distribution transformer. Total Harmonic Distortion (THD) depends largely on the unbalance load andof non-linear load ⦋3⦌ . Equipment that uses semiconductor components can be categorized non linear load. The waves generated by the nonlinear load affect the original wave so that the original wave becomes defective and not a sinusoidal wave anymore. Defective waves will cause a decrease in performance on the equipment and will even be damaged. These defective waves can also cause a decrease in fundamental voltage and RMS current on each channel. Defective waves will affect the distribution of electrical energy and cause the phase of the neutral current to ...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.