In this paper, the fitness of estimating vessel profiles with Gaussian function is evaluated and an amplitude-modified second-order Gaussian filter is proposed for the detection and measurement of vessels. Mathematical analysis is given and supported by a simulation and experiments to demonstrate that the vessel width can be measured in linear relationship with the "spreading factor" of the matched filter when the magnitude coefficient of the filter is suitably assigned. The absolute value of vessel diameter can be determined simply by using a precalibrated line, which is typically required since images are always system dependent. The experiment shows that the inclusion of the width measurement in the detection process can improve the performance of matched filter and result in a significant increase in success rate of detection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.