Corneal injury thresholds are determined for conditions not previously explored for CO2 laser radiation, including multiple-pulse exposures and a systematic investigation of the effect of beam diameter on single-pulse damage thresholds. Multiple-pulse exposures from pulse trains up to 999 pulses, having pulse repetition frequencies between 1 and 100 Hz and individual pulse durations between 10(-3) and 0.5 s, were explored. Damage thresholds are discussed in terms of an approximate critical temperature model, the damage integral model and other empirical correlations. Single-pulse exposures are accurately correlated by an empirical critical temperature model in which the critical temperatures have a weak dependence on exposure duration. However, certain aspects of the single-pulse damage data led us to propose a new thermal damage model that incorporates an endothermic phase transition as the damage mechanism. This physical model accurately correlates single-pulse damage for exposures between 10(-3) and approximately 10 s.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.