Aims Periprosthetic femoral fractures (PPF) are a serious complication of total hip arthroplasty (THA) and are becoming an increasingly common indication for revision arthroplasty with the ageing population. This study aimed to identify potential risk factors for PPF based on an analysis of registry data. Methods Cases recorded with PPF as the primary indication for revision arthroplasty in the German Arthroplasty Registry (Endoprothesenregister Deutschland (EPRD)), as well as those classified as having a PPF according to the International Classification of Diseases (ICD) codes in patients’ insurance records were identified from the complete datasets of 249,639 registered primary hip arthroplasties in the EPRD and included in the analysis. Results The incidence of PPFs was higher (24.6%; 1,483) than reported in EPRD annual reports listing PPF as the main reason for revision (10.9%; 654). The majority of fractures occurred intraoperatively and were directly related to the implantation process. Patients who were elderly, female, or had comorbidities were at higher risk of PPFs (p < 0.001). German hospitals with a surgical volume of < 300 primary procedures per year had a higher rate of PPFs (p < 0.001). The use of cemented and collared prostheses had a lower fracture risk PPF compared to uncemented and collarless components, respectively (both p < 0.001). Collared prostheses reduced the risk of PPF irrespective of the fixation method and hospital’s surgical volume. Conclusion The high proportion of intraoperative fractures emphasises the need to improve surgeon training and surgical technique. Registry data should be interpreted with caution because of potential differences in coding standards between institutions. Cite this article: Bone Joint J 2021;103-B(4):650–658.
National joint registries are gaining more and more importance in the fields of implant monitoring/outlier detection and quality of care. The German Arthroplasty Registry (EPRD) was established in 2010 for the purpose of observing the impact of primary hip and knee arthroplasty on the German population. Having now over one million documentations, we introduce the structure of the EPRD and detail the process of data collection. We report on some preliminary trends and contrast these with findings from other joint registries. We introduce the overhauled Arthroplasty Library, that resulted from an international collaboration with National Joint Registry of England, Wales and Northern Ireland. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180064
The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.
Background: Prosthetic joint infection (PJI) is one of the most frequent and devastating causes of shortterm revision total knee arthroplasty (TKA). In vitro evidence suggests ceramic surfaces demonstrate resistance to biofilm, but the clinical effect of bearing surface modifications on the risk of PJI remains unclear. This premier registry-based study examines the influence of ceramic bearing surface coatings on the outcome in cemented primary TKA. Methods: In total, 117,660 cemented primary TKAs in patients with primary osteoarthritis recorded in the German arthroplasty registry since 2012 were followed up for a maximum of 3 years. The primary endpoint was risk of revision for PJI on ceramic coated and uncoated cobalt-chromium-molybdenum femoral components. Propensity score matching for age, gender, obesity, diabetes mellitus, depression and Elixhauser comorbidity index, and substratification on common design twins with and without coating was performed. Results: In total, 4637 TKAs (85.1% female) with a ceramic-coated femoral component were identified, 42 had been revised for PJI and 122 for other reasons at 3 years. No survival advantage due to the risk of revision for PJI could be determined for ceramic-coated components. Revision for all other reasons demonstrated a significant higher rate for TKAs with ceramic-coated components. However, the results of this were confounded by a strong prevalence (20.7% vs 0.3%) of metal sensitivity in the ceramic-coated group. Conclusion:No evidence of reduced risk for PJI due to ceramic-coated implants in cemented primary TKA was found. Further analysis for revision reasons other than PJI is required.
The German Arthroplasty registry (EPRD) has shown that different prosthesis systems have different rates of secondary patellar resurfacing: four years after implantation, the posterior-stabilized (PS) Vega prosthesis has a 3.2% risk of secondary patellar resurfacing compared to the cruciate-retaining (CR) Columbus prosthesis at 1.0% (both Aesculap AG, Tuttlingen, Germany). We hypothesized that PS implants have increased retropatellar pressure and a decreased retropatellar contact area compared to a CR design, which may lead to an increased likelihood of secondary patellar resurfacing. Eight fresh frozen specimens (cohort 1) were tested with an established knee rig. In addition, a possible influence of the registry-based patient collective (cohort 2) was investigated. No significant differences were found in patient data–cohort 2-(sex, age). A generally lower number of PS system cases is noteworthy. No significant increased patella pressure could be detected with the PS design, but a lower contact area was observed (cohort 1). Lower quadriceps force (100°–130° flexion), increased anterior movement of the tibia (rollback), greater external tilt of the patella, and increasing facet pressure in the Vega PS design indicate a multifactorial cause for a higher rate of secondary resurfacing which was found in the EPRD patient cohort and might be related to the PS’ principle function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.