Conventional thoracic 4DCBCT scans take 1,320 projections over 4 minutes. This paper investigates 7 which reconstruction algorithms best leverage Respiratory-Motion-Guided (RMG) acquisition in 8 order to reduce scan time and dose while maintaining image quality. 9We investigated a 200 projection, on average 1-minute RMG acquisition. RMG acquisition ensures 10 even angular separation between projections at each respiratory phase by adjusting the imaging gantry 11 rotation to the patient respiratory signal in real time. 12 Conventional 1,320 projection data and RMG 200 projection data were simulated from 4DCT 13 volumes of 14 patients. Each patient had an initial 4DCT reconstruction, treated as a planning 4DCT, 14 and a 4DCT reconstruction acquired later, used for 4DCBCT data simulation and evaluation. 15Reconstructions were computed using the Feldkamp-David-Kress (FDK), McKinnon-Bates (MKB), 16RecOnstructiOn using Spatial and TEmporal Regularization (ROOSTER), and Motion Compensated 17 FDK (MCFDK) algorithms. We also introduced and evaluated a novel MCMKB algorithm. 18
Non-circular orbits in cone-beam CT (CBCT) imaging are increasingly being studied for potential benefits in field-of-view, dose reduction, improved image quality, minimal interference in guided procedures, metal artifact reduction, and more. While modern imaging systems such as robotic C-arms are enabling more freedom in potential orbit designs, practical implementation on such clinical systems remains challenging due to obstacles in critical stages of the workflow, including orbit realization, geometric calibration, and reconstruction. In this work, we build upon previous successes in clinical implementation and address key challenges in the geometric calibration stage with a novel calibration method. The resulting workflow eliminates the need for prior patient scans or dedicated calibration phantoms, and can be conducted in clinically relevant processing times.
Purpose Interventional treatments of aneurysms in the carotid artery are increasingly being supplemented with three‐dimensional (3D) x‐ray imaging. The 3D imaging provides additional information on device sizing and stent malapposition during the procedure. Standard 3D x‐ray image acquisition is a one‐size fits all model, exposing patients to additional radiation and results in images that may have cardiac‐induced motion blur around the artery. Here, we investigate the potential of a novel dynamic imaging technique Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) to personalize image acquisition by adapting the gantry velocity and projection rate in real‐time to changes in the patient’s electrocardiogram (ECG) trace. Methods We compared the total number of projections acquired, estimated carotid artery widths and image quality between ACROBEAT and conventional (single rotation fixed gantry velocity and acquisition rate, no ECG‐gating) scans in a simulation study and a proof‐of‐concept physical phantom experimental study. The simulation study dataset consisted of an XCAT digital software phantom programmed with five patient‐measured ECG traces and artery motion curves. The ECG traces had average heart rates of 56, 64, 76, 86, and 100 bpm. To validate the concept experimentally, we designed and manufactured the physical phantom from an 8‐mm diameter silicon rubber tubing cast into Phytagel. An artery motion curve and the ECG trace with an average heart rate of 56 bpm was passed through the phantom. To implement ACROBEAT on the Siemens ARTIS pheno angiography system for the proof‐of‐concept experimental study, the Siemens Test Automation Control System was used. The total number of projections acquired and estimated carotid artery widths were compared between the ACROBEAT and conventional scans. As the ground truth was available for the simulation studies, the image quality metrics of Root Mean Square Error (RMSE) and Structural Similarity Index (SSIM) were also utilized to assess image quality. Results In the simulation study, on average, ACROBEAT reduced the number of projections acquired by 63%, reduced carotid width estimation error by 65%, reduced RMSE by 11% and improved SSIM by 27% compared to conventional scans. In the proof‐of‐concept experimental study, ACROBEAT enabled a 60% reduction in the number of projections acquired and reduced carotid width estimation error by 69% compared to a conventional scan. Conclusion A simulation and proof‐of‐concept experimental study was completed applying a novel dynamic imaging protocol, ACROBEAT, to imaging the carotid artery. The ACROBEAT results showed significantly improved image quality with fewer projections, offering potential applications to intracranial interventional procedures negatively affected by cardiac motion.
Conventional 4DCBCT captures 1320 projections across 4 min. Adaptive 4DCBCT has been developed to reduce imaging dose and scan time. This study investigated reconstruction algorithms that best complement adaptive 4DCBCT acquisition for reducing imaging dose and scan time whilst maintaining or improving image quality compared to conventional 4DCBCT acquisition using real patient data from the first 10 adaptive 4DCBCT patients. Adaptive 4DCBCT was implemented in the ADaptive CT Acquisition for Personalized Thoracic imaging clinical trial. Adaptive 4DCBCT modulates gantry rotation speed and kV acquisition rate in response to the patient’s real-time respiratory signal, ensuring even angular spacing between projections at each respiratory phase. We examined the first 10 lung cancer radiotherapy patients that received adaptive 4DCBCT. Fast, 200-projection scans over 60–80 s, and slower, 600-projection scans over ∼240 s, were obtained after routine patient treatment and compared against conventional 4DCBCT acquisition. Adaptive 4DCBCT acquisitions were reconstructed using Feldkamp−Davis−Kress (FDK), McKinnon–Bates (MKB), Motion Compensated FDK (MCFDK) and Motion Compensated MKB (MCMKB) algorithms. Reconstructions were assessed via, Structural SIMilarity (SSIM), Signal-to-Noise-Ratio (SNR), Contrast-to-Noise-Ratio (CNR), Tissue Interface Sharpness of Diaphragm (TIS-D) and Tumor (TIS-T). The 200- and 600-projection adaptive 4DCBCT acquisition corresponded to 85% and 55% reduction in imaging dose, shorter and similar scan times of approximately 90 s and 236 s respectively, compared to conventional 4DCBCT acquisition. 200- and 600-projection adaptive 4DCBCT reconstructions achieved more than 0.900 SSIM relative to conventional 4DCBCT acquisition. Compared to conventional 4DCBCT acquisition, 200-projection adaptive 4DCBCT reconstructions achieved higher SNR, CNR, TIS-T, TIS-D with motion compensated algorithms, MCFDK (208%, 159%, 174%, 247%) and MCMKB (214%, 173%, 266%, 245%) respectively. The 200-projection adaptive 4DCBCT MCFDK- and MCMKB-reconstruction results show image quality improvements are possible even with 85% fewer projections acquired. We established acquisition-reconstruction protocols that provide substantial reductions in imaging time and dose whilst improving image quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.