ISO/CD 18857-2 (International Organization for Standardization, Geneva) describes a new international standard method for the determination of octylphenol, nonylphenol, their mono- and diethyoxylates, and bisphenol A in nonfiltered samples of drinking, ground, surface, and wastewater. The method is based on the extraction of the analytes from an acidified water sample by solid phase extraction, solvent elution, derivatization, and determination by gas chromatography with mass spectrometric detection. For validation of this method, 14 laboratories from 4 different countries in Europe and Canada participated in an interlaboratory trial to determine the performance characteristics of the method, which are intended for publication in the corresponding standard. The interlaboratory trial was evaluated according to ISO 5725-2 and included two duplicate nonfiltered water samples: surface water containing the target compounds in an analyte concentration range from 0.05 to 0.4 microg/L and wastewater containing the target compounds in a concentration ranged from 0.1 to 5 microg/L. The repeatability variation coefficients (within-laboratory precision) varied for all samples and compounds between 1.9 and 7.8%, showing a sufficiently high repeatability of the method. The reproducibility variation coefficients (between-laboratory precision) were found to vary within a satisfactory range of 10.0-29.5% for surface water and 10.8-22.5% for wastewater. The recoveries as a measure of accuracy varied from 98.0 to 144.1% for surface water and from 95.4 to 108.6% for wastewater. The determined concentrations of the samples compared well to the "true" values, thus showing very satisfactory accuracy of the method. In the chromatogram of the surface water sample, a high unresolved background made up of coextractable matrix compounds was apparent. It is conceivable that compounds from this background may be responsible for enhanced recoveries of 144.1% for 4-nonylphenol (mixture of isomers) and of 123.4% for 4-nonylphenol monoethoxylate (mixture of isomers) in the surface water samples. The isotope-marked standard compounds developed in this context proved to be reliable internal standards that allow a precise and accurate quantitation of all compounds specified in ISO/CD 18857-2. The results of the interlaboratory trial confirmed that the analytical method is robust and reliable and can be used as a standard method to analyze the target compounds in water samples.
Summary:The substances which are expulsed from the water sample by E nitrogen current are first adsorbed on a column filled with Tenax GC and subsequently expulsed a t 200 O C and fed into the gas-chromatographic column. The parallel detection improves the identification of individual substances and makes the detection of aromatics possible a t the same time. Characteristics of the process (detection limit, standard deviation, coefficient of variation, rate of retrieval) are determined and examples of analysis are given. For a water sample of 10 ml the detection limit !ies a t or below 1 yg/l.
Einfiihrung
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.