Background: An important part of the investigation of pleural effusion is the identification of markers that help separate exudate from transudate. Objectives: The purposes of this study were to compare the accuracy of published and new sets of criteria to distinguish between exudative and transudative pleural effusions, and to determine whether serum biochemical analysis is necessary. Methods: An externally validated cohort study was performed. Pleural effusions were determined to be transudative or exudative on the basis of an assessment of the medical record by two clinicians blinded to biochemical results. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and area under the receiver operating characteristic curve were determined for each proposed combination of criteria. Results: Pleural fluid analysis was available for 311 thoracenteses in the main cohort and for 112 thoracenteses in the validation cohort. The best sensitivity (97% [95% CI 94–99]) and negative likelihood ratio (0.04 [95% CI 0.02–0.08]) for identifying exudative effusions were observed with criteria combining pleural fluid lactate dehydrogenase greater than 0.6 the upper limit of normal serum lactate dehydrogenase and pleural fluid cholesterol greater than 1.04 mmol/L (40 mg/dL). The overall diagnostic accuracy was similar to Light’s criteria. Findings were similar in the validation cohort. Conclusions: Our proposed criteria using simultaneously pleural fluid lactate dehydrogenase and pleural fluid cholesterol can identify an exudate with a sensitivity and an overall diagnostic accuracy similar to Light’s criteria. It avoids simultaneous blood sampling, thus reducing patient discomfort and potential costs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.