Summary. Triclocarban (TCC) and triclosan (TCS) are used in a wide range of household and personal care products and have been the most frequently detected organic pollutants in both wastewater and surface water. This paper presented a rapid analytical method for simultaneous determination of TCC and TCS in wastewater. The method involves the extraction and cleanup of the target compounds by using silicon dioxide/polystyrene composite microspheres solid-phase extraction and detection with ultra-high-pressure liquid chromatography. Under the optimized conditions, the limits of detection were 0.028 µg/L and 0.040 µg/L for TCC and TCS, respectively. Under the concentrations of the spiking level ranging from 0.100 µg/L to 2.000 µg/L, the spiked recoveries of TCC and TCS in wastewater samples achieved in the range of 89.5-102.8% with RSD below 6.3% for TCC and 95.5-103.6% with RSD below 6.9% for TCS. This method was successfully used in monitoring the water samples from three traditional wastewater treatment plants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.