A 73-year-old female was found to have prolonged thrombin and reptilase times in the immediate post-operative period. These abnormalities were not corrected by the addition of normal plasma. They were subsequently shown to be due to an IgG immunoglobulin which inhibited fibrin monomer polymerization. The IgG immunoglobulin activity could be neutralized completely by prior incubation with either patient or normal fibrinogen, uncrosslinked fibrin monomers or IgG antisera. No inhibitory effect on thrombin activity, fibrinopeptide A release or on the fibrin cross-linking reaction of factor XIIIa could be detected. Purified patient fibrinogen was functionally normal as demonstrated by normal fibrinogen-fibrin polymerization and fibrinopeptide A release. No underlying cause for this phenomenon was found. The presence of the inhibitor was associated with excessive blood loss during the post-operative period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.