The Persian Gulf is one of the aquatic ecosystems which has recently faced with different pollutions. Cooling water discharges due to various industries such as power plants can cause important disorders on present ecosystem balance because of its high temperature. Obviously, due to thermal pollution, a great number of aquatic creatures face with a new situation that they can not tolerate. Thermal pollution leads to their migration, creates a potential for new coming species which in turn can thoroughly change the marine ecosystem feature. The other impacts of this phenomenon are: disorders in reproduction, nourishment and other biological habits. In this research, thermal pollution due to Bandar Abbas Thermal Power Plant (BATP) development plan was modeled using MIKE21 software. In order to avoid a decrease on the power plant efficiency in development plan, the distance between inlet and outlet was determined by comparing the results of different scenarios and economical aspects. After determining the distance between inlet and outlet, the water temperature in the coastal area was compared with standards of Iranian Department of the Environment (DOE). The model results represent that the water temperature, in Bandar Abbas coastal area, exceeds than the permissible limit (3 o C) in a distance equal to 200 m. far from the discharging location, and in order to reduce its harmful impacts, some suggestions are made to reduce the associated thermal pollution.
The Persian Gulf is one of the aquatic ecosystems which has recently been faced with different pollutions. Cooling water discharges due to various industries such as power plants can cause important disorders on the present ecosystem balance and on aquatic creatures because of their high temperature. Thermal pollution leads to their migration, creates a potential for new coming species which in turn can thoroughly change the marine ecosystem feature. In this research, thermal pollution due to the Bandar Abbas Thermal Power Plant (BATP) development plan was modeled using MIKE21 software. In order to avoid a decrease in the power plant efficiency in the development plan, the distance between the inlet and outlet was determined by comparing the results of different scenarios and economical aspects. After determining the distance between the inlet and outlet, the water temperature in the coastal area was compared with the standards of the Iranian Department of the Environment (DOE). The model results show that the water temperature, in Bandar Abbas coastal area, exceeds the permissible limit (3°C) at a distance equal to 200 m from the discharging location, and in order to reduce its harmful impacts, some suggestions are made to reduce the associated thermal pollution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.