Aims:To describe liquefied after cataract (LAC) and its surgical management following an uneventful phacoemulsification with posterior chamber in-the-bag intraocular lens (IOL) implantation and continuous curvilinear capsulorrhexis (CCC).Design:Interventional case series.Materials and Methods:Eleven patients with LAC, following uneventful phacoemulsification with CCC and in-the-bag IOL implantation were enrolled. After the basic slit lamp examination, each case was investigated with Scheimpflug photography and ultrasound biomicroscopy (UBM). Each case was treated with capsular lavage. Biochemical composition of the milky fluid was evaluated and ring of anterior capsular opacity (ACO) was examined under electron microscope.Results:All 11 cases presented with blurring of vision after 6-8 years of cataract surgery with IOL implantation. All cases had IOL microvacuoles, 360° anterior capsule, and anterior IOL surface touch along with ACO, ring of Soemmering, and posterior capsule distension filled with opalescent milky fluid with whitish floppy or crystalline deposits. Biochemically, the milky fluid contained protein (800 mg/dl), albumin (100 mg/dl), sugar (105 mg/dl), and calcium (0.13%) and was bacteriologically sterile. Histologically, the dissected ACO showed fibrous tissue. All cases were successfully treated with capsular lavage with good visual recovery and with no complication. There was no recurrence of LAC during 2 years postoperative follow-up in any of the cases.Conclusions:LAC is a late complication of standard cataract surgery. It may be a spectrum of capsular bag distension syndrome (CBDS) without shallow anterior chamber and secondary glaucoma. Capsular bag lavage is a simple and effective treatment for LAC and a safe alternative to neodymium-doped yttrium aluminum garnet (Nd-YAG) capsulotomy.
Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.