In this cohort of patients, TEE confirms the role of 'gold standard' exam for the detection of PFO; the non-invasive methods, and the TTE in particular, present a good diagnostic accuracy, but are inferior to the TEE because of the low negative predictive value and the non-optimal detection of small shunts. If the only purpose of TEE is the detection of significative interatrial shunt, TEE can be replaced by TTE. The R3DTE presents a good diagnostic accuracy, provides a better anatomical definition of the interatrial septum, and may have a role in this setting of patients, but does not add a lot to the TTE for the diagnosis.
BACKGROUND:\ud
\ud
Because 20% to 40% of patients undergoing cardiac resynchronization therapy (CRT) do not respond to it, identification of potential factors predicting response is a relevant research topic.\ud
HYPOTHESIS:\ud
\ud
There is a possible association between right ventricular function and response to CRT.\ud
METHODS:\ud
\ud
We analyzed 227 patients from the Cardiac Resynchronization Therapy Modular Registry (CRT-MORE) who received CRT according to current guidelines from March to December 2013. Response to therapy was defined as a decrease of ≥15% in left ventricular end-systolic volume (LVESV) at 6 months.\ud
RESULTS:\ud
\ud
The tricuspid annular plane systolic excursion (TAPSE) value that best predicted improvement in LVESV (sensitivity 68%, specificity 54%) was 17 mm. Stratifying patients according to TAPSE, LVESV decreased ≥15% in 78% of patients with TAPSE >17 mm (vs 59% in patients with TAPSE ≤17 mm; P = 0.006). At multivariate analysis, TAPSE >17 mm was independently associated with LVESV improvement (odds ratio: 1.97, 95% confidence interval: 1.03-3.80, P < 0.05), together with ischemic etiology (odds ratio: 0.39, 95% confidence interval: 0.20-0.75, P < 0.01). These results were confirmed for New York Heart Association class III to IV patients (79% echocardiographic response rate in patients with TAPSE >17 mm vs 55% in patients with TAPSE <17 mm; P = 0.012).\ud
CONCLUSIONS:\ud
\ud
Baseline signs of right ventricular dysfunction suggest possible remodeling after CRT. A TAPSE value of 17 mm was identified as a good cutoff for predicting a better response to CRT in patients with both mildly symptomatic and severe heart failure
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.