The electrophoretic behavior of water-soluble anionic porphyrins, such as meso-tetrakis(4-carboxyphenyl) porphyrin (TCPP), meso-tetrakis(4-sulfonatophenyl) porphyrin (TSPP) and its zinc(II) and copper(II) complexes (ZnTSPP and CuTSPP, respectively) has been studied by capillary zone electrophoresis using fused-silica capillaries. The selectivity of the separation is strongly dependent on the type and concentration of betacyclodextrin (betaCD) or the O-methylated derivatives added to the background electrolyte. CuTSPP and TSPP can be separated using a pH 2.5 aqueous sodium phosphate buffer in the presence of 1 mM betaCD. Resolution is poorer or absent employing alkylated betaCDs, such as the heptakis (2,6-di-O-methyl)-beta-cyclodextrin or the heptakis(2,3,6-triO-methyl)-beta-cyclodextrin, as additives. On the other hand, separation of TSPP from its copper and zinc complexes has been achieved using a pH 7.0 aqueous sodium phosphate buffer, in the presence of 0.75 mM betaCD and 20% dimethyl sulfoxide (DMSO) as organic modifier. Under such conditions, the calibration curve for quantitative analysis of copper(II) was obtained. A rationale for the observed behavior will be presented and discussed on the basis of binding and protonation equilibria and a simple mathematical model.
The water soluble 5-p-aminophenyl)-10,15,20-tris(p-sulfonatophenyl) porphyrin, 4, acts as an extremely efficient chromogenic reagent for the detection of very low amounts of nitrites. The amino group of porphyrin 4 reacts smoothly with nitrite in acidic conditions 0.2 M HCl) producing the corresponding diazo-porphyrin derivative which is stable and does not show any appreciable hydrolysis to phenol within 6 h. The reaction is carried out in the presence of 25 mM heptakis-(2,6-di-O-methyl)-beta-cyclodextrin that prevents precipitation of the protonated form of porphyrins 4 or 5 due to the formation of strong inclusion complexes. The capillary zone electrophoresis of the diazoporphyrin and amino-porphyrin mixture shows severe peak tailing. However, symmetrical peaks can be obtained by adding 5 mM beta-cyclodextrin to the background electrolyte (20 mM phosphate buffer, pH 7.0). Calibration curve for nitrite analysis is linear up to 0.25 mM nitrite and the detection limit (at a signal-to-noise ratio of 3) has been estimated to be a 1 microM (50 ppb) of nitrite concentration in aqueous solutions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.