Pathogens and fecal indicator bacteria occurrence and removal were studied for a period of 6 months at the Montreal Urban Community wastewater treatment facility. With a capacity of about 7.6 million cubic metres per day (two billion U.S. gallons per day), it is the largest primary physico-chemical treatment plant in America. The plant discharges a nondisinfected effluent containing about 20 mg/L of suspended matter and 0.5 mg/L of total phosphorus on the basis of average annual concentrations. BDO5 (annual mean) is 75 mg/L before treatment and 32 mg/L after treatment. Samples were collected for a period of 6 months, and they demonstrated that the plant was not efficient at removing indicator bacteria and the pathogens tested. Fecal coliforms were the most numerous of the indicator bacteria and their removal averaged 25%. Fecal streptococci removal was 29%, while Escherichia coli removal was 12%. In untreated sewage, fecal coliforms, E. coli, and human enteric viruses were more numerous in summer and early autumn. Fecal streptococci counts remained relatively similar throughout the period. Clostridium perfringens removal averaged 51%. Giardia cysts levels were not markedly different throughout the study period, and 76% of the cysts were removed by treatment. Cryptosporidium oocyst counts were erratic, probably due to the methods, and removal was 27%. Human enteric viruses were detected in all samples of raw and treated wastewater with no removal observed (0%). Overall, the plant did not perform well for the removal of fecal indicator bacteria, human enteric viruses, or parasite cysts. Supplementary treatment and disinfection were recommended to protect public health. Various alternatives are being evaluated.
Pathogens and fecal indicator bacteria occurrence and removal were studied for a period of 6 months at the Montreal Urban Community wastewater treatment facility. With a capacity of about 7.6 million cubic metres per day (two billion U.S. gallons per day), it is the largest primary physico-chemical treatment plant in America. The plant discharges a nondisinfected effluent containing about 20 mg/L of suspended matter and 0.5 mg/L of total phosphorus on the basis of average annual concentrations. BDO5 (annual mean) is 75 mg/L before treatment and 32 mg/L after treatment. Samples were collected for a period of 6 months, and they demonstrated that the plant was not efficient at removing indicator bacteria and the pathogens tested. Fecal coliforms were the most numerous of the indicator bacteria and their removal averaged 25%. Fecal streptococci removal was 29%, while Escherichia coli removal was 12%. In untreated sewage, fecal coliforms, E. coli, and human enteric viruses were more numerous in summer and early autumn. Fecal streptococci counts remained relatively similar throughout the period. Clostridium perfringens removal averaged 51%. Giardia cysts levels were not markedly different throughout the study period, and 76% of the cysts were removed by treatment. Cryptosporidium oocyst counts were erratic, probably due to the methods, and removal was 27%. Human enteric viruses were detected in all samples of raw and treated wastewater with no removal observed (0%). Overall, the plant did not perform well for the removal of fecal indicator bacteria, human enteric viruses, or parasite cysts. Supplementary treatment and disinfection were recommended to protect public health. Various alternatives are being evaluated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.