Open carpal tunnel release is a common and successful treatment of median neuropathy at the wrist (carpal tunnel syndrome). We report a case of delayed ulnar neuropathy at the wrist with onset 2 months after open carpal tunnel release. Clinical findings, electrophysiological studies, magnetic resonance imaging, and surgical exploration demonstrated ulnar nerve compression at Guyon's canal resulting from translocation of the carpal tunnel contents. To our knowledge, this is an unreported complication of open carpal tunnel release that merits wide appreciation.
Examinations of the skeletal system have historically used 'detail' x-ray film-screen combinations having film-lightbox image quality that is challenging to replicate in a soft-copy environment. A review of the basic diagnostic imaging tasks for this sub-specialty is presented, including resolution and gray scale requirements for visualization of subtle fractures, bone mineral loss, implant loosening, and soft tissue disease. Measurements are made to specify image quality metrics in terms of Michelson contrast, spatial resolution, and dynamic range. Image contrast requirements are presented using Just Noticeable Differences (JND) values based upon the National Electrical Manufacturers Association (NEMA) and Digital Imaging Communication in Medicine (DICOM) Grayscale Softcopy Standard ofAnnex B, Part 14. (1). Image data is used to calculate modulation transfer function (MTF) for a type of liquid crystal active matrix display (monochrome) being considered for clinical use.No differences in visualization of image contrast or detail of subtle bone pathology was observed between film or cathode ray tube (CRT) viewing for any of the images, provided that the CRT display included window-level adjustment, zooming, and image re-location. This added activity on the part of the radiologist results in greater fatigue with CRT viewing.Measurements of image pixel data revealed that 'subtle' pathology wth orthopedic examinations had contrast values in the range of 1 to 10%. Actual measurements of displayed film and CRT conspicuity (using the metric of JND values) at the regions of pathology show no overall average change. However, about one-half of the images actually had a loss of JND values (mean loss of4O%) when viewed on CRT rather than on filmThe use of computed radiographic imaging plates having 1 00 micron resolution allows for the visualization of trabecular bone detail (mean diameter of 1 00 microns) on both film and with display optimized CRT. This implies that an equivalency of image quality detail for a liquid crystal display for orthopedic viewing would be '-1OO microns, i.e. at least 5 line pairs per mm. Our measurements of pixel size (100 microns) and fill factor (0.36) for the liquid crystal display we tested gave satisfactory results as determined by calculations ofMTF (7 line pairs per millimeter). However, the fill factor of this display substantially reduces overall luminance, and potentially contrast.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.