Abstract. To determine the efficiency of multi-MW wind turbines, the torque
measurement in wind turbine test benches has to be performed with an accuracy
better than 0.2 %. To this end, the torque measurement has to be traced
to national standards in the MN m range. This can be done by using a novel
torque transfer standard in combination with a newly developed torque
calibration procedure under constant rotation, which are both presented and
discussed in this paper. The calibration procedure was performed on a 4 MW
wind turbine test bench and the evaluation of the calibration result,
including a measurement uncertainty, is explained in detail.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.