Purpose: The aim of this study was to compare the accuracy of digital dental impressions with the accuracy of impressions obtained via conventional techniques. Methods: Two different master models were created, one with parallel implants (model 1) and the other with non-parallel implants (model 2). These reference master models included 4 Klockner KL RP implants (Klockner Implant System SA, Barcelona, Spain), which were juxta-placed and equidistant in the intermentoneal region. In model 1 the implants were placed parallel to each other, whereas in model 2 the implants were placed such that there was a divergence angle of 15° between the more distal implants, and a convergence angle of 15° between the two central implants. A total of four types of impressions were obtained from model 1 (four groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression groups for dragging copings, without splinting; open tray impressions for ferrules; and impressions obtained using the 3MTM True Definition Scanner system. For model 2 three groups were created (three groups, n = 10 each), including closed tray impressions with replacement abutments; open tray impression for dragging copings, without splinting; and impressions obtained using the 3MTM True Definition Scanner system. The master models and the models obtained using conventional methods were digitalized in order to compare them via an extraoral high-resolution scanner (Imetric IScan D104i, Porretruy, Switzerland). The STL (Stereo Lithography (format for transferring 3 dimensional shape information)) digital values were loaded into reverse-engineering software and superimposed with their respective STL master models in order to evaluate deviations in three dimensions. We then analyzed the squares of the deviations in the three axes and evaluated the median and the sum of the deviation square. Statistical analysis was performed using the IBM Corp. Released 2016. IBM SPSS Statistics for Windows, Version 24.0. Armonk, NY: IBM Corp. The normality of the distributions was analyzed according to a Kolmogorov-Smirnov test. The median comparison was performed using the differences between the medians, analyzed using non-parametric Kruskal-Wallis and Mann-Whitney tests with a significance level of p < 0.05. Results: For model 1, the deviations of the digital impressions were smaller than those associated with the conventional techniques. The sum value in group D was 1,068,292, which was significantly lower than those of groups A, B, and C, which were shown to be 2,114,342, 2,165,491, and 1,265,918, respectively. This improvement was not observed when using model 2, however, where the conventional techniques yielded similar results. Group F simultaneously presented the lowest total square sum of the three deviations (1,257,835), indicating a significantly higher accuracy for this group in model 2, while the sum values were 1,660,975 and 1,489,328 for groups E and G, respectively. Conclusion: Digital impressions of full-arch models were abl...
Uterosacral ligament nodules with ultrasound measurements of 1.75 cm and 1.95 cm on the right and left sides, respectively, significantly increase the risk of ureteral involvement. Even with the association of other ultrasound variables, there was no improvement in sensitivity. Therefore, USL nodule size is a key measure for therapeutic planning and consent of the patient.
Introduction. Digital impressions in implant dentistry rely on many variables, and their accuracy, particularly in complete edentulous patients, is not well understood. Aim. The purpose of this literature review was to determine which factors may influence the accuracy of digital impressions in implant dentistry. Emphasized attention was given to the design of the intra-oral scan body (ISB) and scanning techniques. Materials and methods. A Medline, PubMed and EBSCO Host databases search, complemented by a hand search, was performed in order to select relevant reports regarding the appliance of digital impressions in implant dentistry. The search subject included but was not limited to accuracy of digital impressions in implant dentistry, digital scanning techniques, the design and material of the ISBs, and the depth and angulation of the implant. The related titles and abstracts were screened, and the remaining articles that fulfilled the inclusion criteria were selected for full-text readings. Results. The literature search conducted for this review initially resulted in 108 articles, among which only 21 articles fulfilled the criteria for inclusion. Studies were evaluated according to five subjects: accuracy of digital impressions in implant dentistry; the design and material of the intra-oral scan bodies; scanning technique; the influence of implants depth/angulations on the digital impression and accuracy of different intra-oral scanner devices. Conclusions. The accuracy of digital impressions in implant dentistry depends on several aspects. The depth/angulation of the implant, the experience of the operator, the intra-oral scanner used, and environmental conditions may influence the accuracy of digital impressions in implant dentistry. However, it seems that ISBs’ design and material, as well as scanning technique, have a major impact on the trueness and precision of digital impressions in implant dentistry. Future research is suggested for the better understanding of this subject, focusing on the optimization of the ISB design and scanning protocols.
Objective The objective of this review was to analyze the impact on ovarian reserve of the different hemostatic methods used during laparoscopic cystectomy. Data Sources The studies were identified by searching electronic databases (MEDLINE, Embase, Cochrane, LILACS) and scanning reference lists of articles. Methods of Study Selection We selected clinical trials that assessed the influence of hemostatic techniques on ovarian reserve in patients with ovarian cysts with benign sonographic appearance submitted to laparoscopic cystectomy by stripping technique. The included trials compared different laparoscopic hemostatic techniques: suture, bipolar electrocoagulation, ultrasonic energy and hemostatic sealants. The outcomes evaluated were level of serum anti-Mullerian hormone (AMH) and antral follicle count (AFC). The possibility of publication bias was evaluated by funnel plots. Tabulation, Integration and Results Twelve trials involving 1,047 patients were evaluated. Laparoscopic suture was superior to bipolar coagulation when evaluating serum AMH and AFC, in the 1st, 3rd, 6th and 12th month after surgery. In the comparison between bipolar and hemostatic sealants, the results favored the use of hemostatic agents. The use of ultrasonic energy was not superior to the use of bipolar energy. Conclusion We recommend suture for hemostasis during laparoscopic cystectomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.