The available meta-analyses have inconclusively indicated the advantages of video-laryngoscopy (VL) in different clinical situations; therefore, we conducted a systematic review and meta-analysis to determine efficacy outcomes such as successful first attempt or time to perform endotracheal intubation as well as adverse events of VL vs. direct laryngoscopes (DL) for double-lumen intubation. First intubation attempt success rate was 87.9% for VL and 84.5% for DL (OR = 1.64; 95% CI: 0.95 to 2.86; I2 = 61%; p = 0.08). Overall success rate was 99.8% for VL and 98.8% for DL, respectively (OR = 3.89; 95%CI: 0.95 to 15.93; I2 = 0; p = 0.06). Intubation time for VL was 43.4 ± 30.4 s compared to 54.0 ± 56.3 s for DL (MD = −11.87; 95%CI: −17.06 to −6.68; I2 = 99%; p < 0.001). Glottic view based on Cormack–Lehane grades 1 or 2 equaled 93.1% and 88.1% in the VL and DL groups, respectively (OR = 3.33; 95% CI: 1.18 to 9.41; I2 = 63%; p = 0.02). External laryngeal manipulation was needed in 18.4% cases of VL compared with 42.8% for DL (OR = 0.28; 95% CI: 0.20 to 0.40; I2 = 69%; p < 0.001). For double-lumen intubation, VL offers shorter intubation time, better glottic view based on Cormack–Lehane grade, and a lower need for ELM, but comparable first intubation attempt success rate and overall intubation success rate compared with DL.
Stress hyperglycemia remains a significant and unsolved medical condition in critically ill children. Treatment for hyperglycemia is controversial and, to date, no recommendations exist from pediatric professional society regarding the management of hyperglycemia in critically ill children. This review summarizes recent work investigating the pathogenesis of stress hyperglycemia, the importance of hypoglycemic episodes and glycemic variability among critically ill patients.
This study aimed to compare the intubation effectiveness of the bébé Vie Scope™ (VieScope) and direct laryngoscopy for emergency intubation in a pediatric manikin model performed by paramedics with and without personal protective equipment for aerosol generating procedures (PPE-AGP). Participants performed endotracheal intubation using VieScope and standard Macintosh laryngoscope (MAC) in two research scenarios: (1) without PPE-AGP, and (2) with PPE-AGP. Fifty-one paramedics without any previous experience with the VieScope participated in this study. In the PPE-AGP scenario, in the VieScope group, the percentage of successful tracheal intubation on the first attempt was higher compared to the MAC group (94.1 vs. 78.4%, p = 0.031), intubation time was shorter (29.8 vs. 33.9 s, p < 0.001), and percentage of glottic opening (POGO) score was higher 91.0 vs 77.8 (p < 0.001). On the Cormack–Lehane scale, intubation with VieScope intubation was associated with higher scores rated at 1 (64.7 vs. 29.4%) than in the MAC group (p = 0.001). For intubation in the non-PPE scenario, there were no statistically significant differences between VieScope and MAC in relation to above parameters. Summarize, the bébé VieScope™ under PPE-AGP wearing conditions has proven to be a useful device for airway management in children providing better visualization of the larynx, better intubation conditions, and a higher success rate of tracheal intubation on the first attempt and reduced intubation time compared to the standard Macintosh laryngoscope.
Ventilator-associated pneumonia (VAP) is a type of pneumonia classified as a nosocomial infection associated with mechanical ventilation which occurs 48–72 hours after endotracheal intubation [...]
We aimed to define reference ranges of glycemic variability indices derived from continuous glucose monitoring data for non-diabetic infants during post-operative intensive care treatment after cardiac surgery procedures. We performed a prospective cohort intervention study in a pediatric intensive care unit (PICU). Non-diabetic infants aged 0–12 months after corrective cardiovascular surgery procedures were fitted upon arrival to the PICU with a continuous glucose monitoring system (iPro2, Medtronic, Minneapolis, MN, USA). Thirteen glycemic variability indices were calculated for each patient. Complete recordings of 65 patients were collected on the first postoperative day. During the first three postsurgical days 5%, 24% and 43% of patients experienced at least one hypoglycemia episode, and 40%, 10% and 15%—hyperglycemia episode, respectively, in each day. Due to significant differences between the first postoperative day (mean glycemia 130 ± 31 mg/dL) and the second and third day (105 ± 18 mg/dL, 101 ± 22.2 mg/dL; p < 0.0001), we proposed two separate reference ranges—for the acute and steady state patients. Thus, for individual glucose measurements, we proposed a reference range between 85 and 229 mg/dL and 69 and 149 mg/dL. For the mean daily glucose level, ranges between 122 and 137 mg/dL and 95 and 110 mg/dL were proposed. In conclusion, rt-CGM revealed a very high likelihood of hyperglycemia in the first postsurgical day. The widespread use of CGM systems in a pediatric ICU setting should be considered as a safeguard against dysglycemic episodes; however, reference ranges for those patients should be different to those used in diabetes care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.