A combination of targeted probes and new imaging technologies provides a powerful set of tools with the potential to improve the early detection of cancer. To develop a probe for detecting colon cancer, we screened phage display peptide libraries against fresh human colonic adenomas for high-affinity ligands with preferential binding to premalignant tissue. We identified a specific heptapeptide sequence, VRPMPLQ, which we synthesized, conjugated with fluorescein and tested in patients undergoing colonoscopy. We imaged topically administered peptide using a fluorescence confocal microendoscope delivered through the instrument channel of a standard colonoscope. In vivo images were acquired at 12 frames per second with 50-microm working distance and 2.5-microm (transverse) and 20-microm (axial) resolution. The fluorescein-conjugated peptide bound more strongly to dysplastic colonocytes than to adjacent normal cells with 81% sensitivity and 82% specificity. This methodology represents a promising diagnostic imaging approach for the early detection of colorectal cancer and potentially of other epithelial malignancies.
Zero-mode waveguides provide a powerful technology for studying single-molecule real-time dynamics of biological systems at physiological ligand concentrations. We customized a commercial zero-mode waveguide-based DNA sequencer for use as a versatile instrument for single-molecule fluorescence detection and showed that the system provides long fluorophore lifetimes with good signal to noise and low spectral cross-talk. We then used a ribosomal translation assay to show real-time fluidic delivery during data acquisition, showing it is possible to follow the conformation and composition of thousands of single biomolecules simultaneously through four spectral channels. This instrument allows high-throughput multiplexed dynamics of single-molecule biological processes over long timescales. The instrumentation presented here has broad applications to single-molecule studies of biological systems and is easily accessible to the biophysical community.D etermining the molecular details of the time evolution of complex multicomponent biological systems requires analysis at the single-molecule level because of their stochastic and heterogeneous nature. Ideally, such experiments would track simultaneously the composition of a biological system (bound ligands, factors, and cofactors) and the conformation of the individual molecules in real time. Single-molecule fluorescence methods, such as total internal reflection fluorescence (TIRF) microscopy, allow the observations of the compositional dynamics (through arrival of fluorescently labeled ligands, factors, or cofactors) and conformational dynamics (through FRET) of single-molecular species. However, these traditional singlemolecule methods are hindered by limitations in maximal fluorescent component concentrations (up to 50 nM) (1), limited simultaneous detection (two to three colors) (2-6), and low throughput (a few hundred molecules at most per experiment) (7). As such, the full potential of single-molecule fluorescence to investigate a range of biological problems under physiologically relevant conditions has not yet been harnessed.Zero-mode waveguides (ZMWs) are small metallic apertures patterned on glass substrates that overcome the concentration restrictions by optically limiting background excitation (8). Each ZMW consists of an ∼150-nm-diameter metallic aperture that restricts the excitation light to a zeptoliter volume, making possible experiments with near-physiological concentrations (up to 20 μM) of fluorescently labeled ligands (1). Previous advances in nanofabrication (9), surface chemistry (10), and detection instrumentation (11) have led to ZMW-based instrumentation capable of the direct observation of DNA polymerization (12), reverse transcription (13), processive myosin motion (14), and translation by the ribosome (15, 16) with multicolor single-molecule detection. However, this sophisticated technology has not been broadly available to the scientific community. Despite multiple efforts to develop ZMW instrumentation, the combined difficulties in fabrica...
This study evaluated new endoscopic OCT technology and demonstrated the feasibility of carrying out UHR OCT imaging in conjunction with standard endoscopy for in vivo real-time imaging of Barrett's esophagus, dysplasia, and esophageal adenocarcinoma. A survey of normal and abnormal upper gastrointestinal tissues was performed using a research prototype OCT system with the highest axial resolution to date, and can serve as a baseline for future investigation.
Confocal imaging can be performed in vivo to assess the functional behavior of tissue in real time for providing pathologic interpretation, representing a new method for histologic evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.