Reports in the field of robotic surgery for gastric cancer are increasing. However, studies only on patients with advanced gastric cancer (AGC) are lacking. This retrospective study was to compare the short-term outcomes of robotic-assisted distal gastrectomy (RADG) and laparoscopic-assisted distal gastrectomy (LADG) with D2 lymphadenectomy for AGC. From December 2014 to November 2019, 683 consecutive patients with AGC underwent mini-invasive assisted distal gastrectomy. Propensityscore matching (PSM) analysis was conducted to reduce patient selection bias. Short-term outcomes were compared between the two groups. The clinical features were well matched in the PSM cohort. Compared with the LADG group, the RADG group was associated with less operative blood loss, a lower rate of postoperative blood transfusion, less volume of abdominal drainage, less time to remove abdominal drainage tube, retrieved more lymph node, and lower rates of surgical complications and pancreatic fistula (P <0.05). However, the time to recovery bowel function, the length of postoperative stay, the rates of other subgroups of complications and unplanned readmission were similar between the two groups (P > 0.05). This study suggests that RADG is a safe and feasible technique with better short-term outcomes than LADG for AGC.Gastric cancer continues to be a major public health problem worldwide, especially in developing countries, such as China 1,2 . Every year, approximately 680,000 new patients are diagnosed with gastric cancer in China; among them, more than 80% of these patients have advanced-stage disease 1,3 . For patients with advanced gastric cancer (AGC), multidisciplinary comprehensive treatment is usually required, and gastrectomy with lymph node dissection is currently considered to be the only curable treatment 4 .In the past few decades, with the development of science and technology, much advanced surgical equipment has been invented, particularly in the field of mini-invasive surgery (MIS). Since laparoscopy-assisted Billroth I gastrectomy was first reported in 1994, several randomized controlled trials (RCTs) have demonstrated that laparoscopic gastrectomy (LG) for AGC is a safe and feasible technique with better short-term outcomes than and similar oncological outcomes to open gastrectomy [5][6][7][8][9] . Although LG has obtained greater acceptance among abdominal surgeons, because of the limitations of laparoscopic instruments, it is difficult to perform precisely, as is the case with D2 lymphadenectomy 10,11 .Robotic surgery systems, as another MIS method, were invented to overcome the drawbacks of laparoscopy and are becoming increasingly accepted by abdominal surgeons. Since Hashizume et al. first reported the use of robotic surgery for gastric cancer in 2002, a number of studies have shown the safety and advantages of robotic
Objective To explore the feasibility of 3D printed customized guides assisting the precise drilling of Kirschner wires in subtalar joint arthrodesis. Methods We retrospectively reviewed the data of 29 patients (30 subtalar joints) who underwent subtalar joint arthrodesis between 1 July 2013 and 31 December 2017. The customized guides were designed on a full‐scale 3D polylactic acid model made from computed tomography (CT) data of patients by Model Intestinal Microflora in Computer Simulation (MIMICS) software, which were manufactured by 3D printing technology. A total of 14 joints used customized guides (experimental group); the remained 16 joints used the traditional method (control group). The time of drilling the Kirschner wires to the correct position, the time of subtalar fusion, American Orthopaedic Foot & Ankle Society (AOFAS) scores, and complications were evaluated in both groups. Results All customized guides were successfully manufactured. In the experimental group, it took 2.1 ± 0.7 min to drill the Kirschner wire to the satisfactory position, and 2 cases needed to be re‐drilled; in the control group, it took 4.6 ± 1.9 min to drill the Kirschner wire to the satisfactory position (P < 0.05), and 8 cases needed to be re‐drilled. No serious complications occurred in both groups during and after the surgery. Postoperative radiographic fusion was confirmed in all cases. No significant difference was observed in the fusion time and AOFAS scores 1 year postoperatively between the two groups (P > 0.05). Conclusion It is safe to apply 3D‐printed customized guides for subtalar joint arthrodesis, which can assist the accurate drilling of Kirschner wires into the appropriate position according to the preoperative plan, and reduce the operation time as well as intraoperative radiation.
Objective To accurately drill the Kirschner wire with the help of the 3D-printed personalized guide and to evaluate the feasibility of the 3D technology as well as the outcome of the surgery. Methods Patients' DICM data of ankle via CT examinations were introduced into the MIMICS software to design the personalized guides. Two 2mm Kirschner wires were drilled with the help of the guides; the C-arm fluoroscopy was used to confirm the position of the wires before applying the cannulated screws. The patients who underwent ankle arthrodesis were divided into two groups. The experimental group adopted the 3D-printed personalized guides, while the control group received traditional method, i.e., drilling the Kirschner wires according to the surgeon's previous experience. The times of completing drilling the Kirschner wires to correct position were compared between the two groups. Regular follow-ups were conducted to statistically analyze the differences in the ankle fusion time and AOFAS scores between the two groups. Results 3D-printed personalized guides were successfully prepared. A total of 29 patients were enrolled, 15 in the experimental group and 14 in the control group. It took 2.2 ± 0.8 minutes to drill the Kirschner wires to correct position in the experimental group and 4.5 ± 1.6 minutes in the control group (p=0.001). No obvious complications occurred in the two groups during and after surgery. Postoperative radiographs confirmed bony fusion in all cases. There were no significant differences in the fusion time (p=0.82) and AOFAS scores at 1 year postoperatively between the two groups (p=0.55). Conclusions The application of 3D-printed personalized guide in assisting the accurate drilling of Kirschner wire in ankle arthrodesis can shorten the operation time and reduce the intraoperative radiation. This technique does not affect the surgical outcome. Trial Registration Number This study is registered on www.clinicaltrials.gov with NCT03626935.
Objective. To test the biomechanical properties of 3D printed tantalum and titanium porous scaffolds. Methods. Four types of tantalum and titanium scaffolds with four alternative pore diameters, #1 (1000-700 μm), #2 (700-1000 μm), #3 (500-800 μm), and #4 (800-500 μm), were molded by selective laser melting technique, and the scaffolds were tested by scanning electronic microscope, uniaxial-compression tests, and Young’s modulus tests; they were compared with same size pig femoral bone scaffolds. Results. Under uniaxial-compression tests, equivalent stress of tantalum scaffold was 411 ± 1.43 MPa, which was significantly larger than the titanium scaffolds ( P < 0.05 ). Young’s modulus of tantalum scaffold was 2.61 ± 0.02 GPa, which was only half of that of titanium scaffold. The stress-strain curves of tantalum scaffolds were more similar to pig bone scaffolds than titanium scaffolds. Conclusion. 3D printed tantalum scaffolds with varying pore diameters are more similar to actual bone scaffolds compared with titanium scaffolds in biomechanical properties.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.