Perioperative changes in the sublingual microcirculatory parameters measured with the SDF-imaging technique appear to be minor, and no association with outcome after major abdominal surgery could be demonstrated. Changes in ScvO2 and serum lactate do not reflect sublingual microcirculatory alterations in this setting.
• It is thought that the better volume-expanding effect of albumin relative to crystalloids is dependent on low endothelial permeability for albumin What This Article Tells Us That Is New• One group of animals were subjected to a 11% hemorrhage and then given either 5% albumin in a volume equal to the shed blood volume or Ringer's acetate at 4.5 times that volume • Another group of animals were subjected to abdominal sepsis, and at 3 h, measured plasma volume loss was replaced with either 5% albumin or with Ringer's acetate in 4.5 times the measured loss • Plasma volume expansion with albumin relative to Ringer's acetate did not differ between the two groups despite different etiologies for the decrease in plasma volume ABSTRACT Background: It is believed that the effectiveness of colloids as plasma volume expanders is dependent on the endothelial permeability for macromolecules. The objective of this study was to test the hypothesis that the plasma volume expanding effect of 5% albumin relative to that of a crystalloid solution is reduced if microvascular permeability is increased. Methods: A control group was resuscitated with either 5% albumin (8 ml/kg) or Ringer's acetate (36 ml/kg) immediately after a hemorrhage of 8 ml/kg (n = 29). In a second group, permeability was increased by inducing sepsis through cecal ligation and incision (n = 28). Three hours after cecal ligation and incision, the animals were resuscitated with either 5% albumin in a ratio of 1:1 relative to the volume of lost plasma, or Ringer's acetate in a ratio of 4.5:1. Results: In the hemorrhage group, plasma volumes at 15 min after resuscitation with albumin or Ringer's acetate had increased by 9.8 ± 2.6 ml/kg (mean ± SD) and 7.4 ± 2.9 ml/kg and were similar at 2 and 4 h. Plasma volume 3 h after cecal ligation and incision had decreased by approximately 7 ml/kg, and at 15 min after resuscitation with albumin or Ringer's acetate it had increased by 5.7 ± 2.9 and 2.4 ± 3.0 ml/kg, respectively (P < 0.05). At 2 and 4 h after resuscitation, plasma volumes did not differ between the groups. Conclusion: This study does not support the hypothesis that the plasma-volume-expanding effect of albumin relative to that of crystalloids is decreased under conditions characterized by increased permeability. ( Anesthesiology 2014; 121:817-24)The first two authors contributed equally to the study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.