ObjectivesThe aim of the work was to find biomarkers identifying patients at high risk of adverse clinical outcomes after TAVI and SAVR in addition to currently used predictive model (EuroSCORE).BackgroundThere is limited data about the role of biomarkers in predicting prognosis, especially when TAVI is available.MethodsThe multi-biomarker sub-study included 42 consecutive high-risk patients (average age 82.0 years; logistic EuroSCORE 21.0%) allocated to TAVI transfemoral and transapical using the Edwards-Sapien valve (n = 29), or SAVR with the Edwards Perimount bioprosthesis (n = 13). Standardized endpoints were prospectively followed during the 12-month follow-up.ResultsThe clinical outcomes after both TAVI and SAVR were comparable. Malondialdehyde served as the best predictor of a combined endpoint at 1 year with AUC (ROC analysis) = 0.872 for TAVI group, resp. 0.765 (p<0.05) for both TAVI and SAVR groups. Increased levels of MDA, matrix metalloproteinase 2, tissue inhibitor of metalloproteinase (TIMP1), ferritin-reducing ability of plasma, homocysteine, cysteine and 8-hydroxy-2-deoxyguanosine were all predictors of the occurrence of combined safety endpoints at 30 days (AUC 0.750–0.948; p<0.05 for all). The addition of MDA to a currently used clinical model (EuroSCORE) significantly improved prediction of a combined safety endpoint at 30 days and a combined endpoint (0–365 days) by the net reclassification improvement (NRI) and the integrated discrimination improvement (IDI) (p<0.05).Cystatin C, glutathione, cysteinylglycine, asymmetric dimethylarginine, nitrite/nitrate and MMP9 did not prove to be significant. Total of 14.3% died during 1-year follow-up.ConclusionWe identified malondialdehyde, a marker of oxidative stress, as the most promising predictor of adverse outcomes during the 30-day and 1-year follow-up in high-risk patients with symptomatic, severe aortic stenosis treated with TAVI. The development of a clinical “TAVIscore” would be highly appreciated. Such dedicated scoring system would enable further testing of adjunctive value of various biomarkers.
The ellipsoidal shell model of the right ventricle is a good model for right ventricular volumetry.
Aim. The aim of this study was to compare the quality of life after transcatheter aortic valve implantation (TAVI) and surgical replacement (SAVR) at one year. Methods. The study included 45 consecutive high-risk patients (average age 82.0 years; logistic Euroscore 22.3%) with symptomatic severe aortic stenosis allocated to TAVI transfemoral, TAVI transapical using the Edwards-Sapien valve or SAVR with the Edwards Perimount bioprosthesis (n=15 in each). The pre-operative characteristics were similar except for more myocardial infarctions in TAVI. The quality of life was assessed using the standardized EQ-5D questionnaire at baseline and on days 30, 90 and 360. The protocol was approved by the local ethics committee and an informed consent was signed. A total of 7 patients (15.5%) died during follow-up. Results. At baseline no significant differences in any of the quality-of-life parameters were found except for usual activities described as "best" (46.7% in SAVR vs. 10.0% in TAVI; P=0.002). At 30 and 90 days surviving patients were similar and at 360 days only the anxiety/depression score was "best" in 83.3% SAVR vs. 59.1% (P=0.046). Functional status improved in all patients (NYHA class I-II in 13.3% at baseline vs. 78.9% at 360-days) and the general health median significantly improved in TAVI patients (from 50 to 67; P=0.001) with a positive trend in SAVR patients (P=0.060). Conclusions. At one year, the general quality of life of high-risk patients had significantly improved after transcatheter aortic valve implantation with a positive trend in surgically treated patients.
After heart transplantation the effect of immunosuppression is monitored by histopathology of endomyocardial biopsy (EMB). EMB is usually carried out under X-ray guidance. Between January 1998 and March 2003, 1,262 biopsies were collected under echo-guidance in 156 patients. The biopsy access was gained through the internal jugular vein, by the standard catheterization technique. The average time of the procedure was 17 min. Four or five specimens were obtained from each patient, with a success rate of 96%. Complications involved two episodes of partial pneumothorax in one patient, atrial flutter in another and ventricular fibrillation in three
After heart transplantation the effect of immunosuppression is monitored by histopathology of endomyocardial biopsy (EMB). EMB is usually carried out under X-ray guidance. Between January 1998 and March 2003, 1,262 biopsies were collected under echo-guidance in 156 patients. The biopsy access was gained through the internal jugular vein, by the standard catheterization technique. The average time of the procedure was 17 min. Four or five specimens were obtained from each patient, with a success rate of 96%. Complications involved two episodes of partial pneumothorax in one patient, atrial flutter in another and ventricular fibrillation in three
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.