Indoor 222Rn concentrations were measured in 37 houses with alpha track detectors placed in water-use rooms near water sources (bathrooms, laundry rooms, and kitchens) and in non-water-use living rooms, dining rooms, and bedrooms away from water sources. Results show that relative contributions of 222Rn to indoor air from water use are insignificant when soil-gas concentrations are high but become increasingly important as the ratio of 222Rn-in-water: 222Rn-in-soil gas increases. High soil-gas 222Rn concentrations may mask 222Rn contributions from water even when waterborne 222Rn concentrations are as high as 750 kBq m-3. Ground water in Precambrian Pikes Peak granite averages 340 kBq m-3 222Rn, vs. 170 kBq m-3 in Precambrian migmatite, but average 222Rn concentrations in soil gas are also lower in migmatite. Because the ratio of 222Rn-in-water: 222Rn-in-soil gas may be consistently higher for houses in migmatite than in Pikes Peak granite, indoor air in houses built on migmatite may have a greater relative contribution from water use even though average 222Rn concentrations in the water are lower. Continuous monitoring of 222Rn concentrations in air on 15-min intervals also indicates that additions to indoor concentrations from water use are significant and measurable only when soil-gas concentrations are low and concentrations in water are high. When soil-gas concentrations were mitigated to less than 150 Bq m-3 in one house, water contributes 20-40% of the annual indoor 222Rn concentration in the laundry room (222Rn concentration in water of 670 kBq m-3). Conversely, when the mitigation system is inactive, diurnal fluctuations and other variations in the soil-gas 222Rn contribution swamp the variability due to water use in the house. Measurable variations in indoor concentrations from water use were not detected in one house despite a low soil-gas contribution of approximately 150 Bq m-3 because waterborne 222Rn concentrations also are low (80 kBq m-3). This result suggests that 222Rn concentrations in water near the recommended EPA limit in drinking water of 11 kBq m-3 may not contribute measurable amounts of 222Rn to indoor air in most houses.
The contribution of 222Rn from domestic water wells to indoor air was investigated in a study of 28 houses near Conifer, CO. Air concentrations determined by alpha-track detectors (ATDs) and continuous radon monitors were compared with the predictions of a single-cell model. In many of the houses, the water supply was shown to contribute significantly to levels of indoor 222Rn. The data from the ATD study were augmented with a continuous monitoring study of a house near Lyons, CO. The well water in that house has the highest known concentration of 222Rn in water yet reported (93 MBq m-3). The temporal pattern in the indoor 222Rn concentration corresponds to water-use records. In general, it is difficult to quantify the proportion of indoor radon attributable to water use. Several lines of evidence suggest that the single-cell model underestimates this proportion. Continuous-monitoring data, although useful, are impractical due to the cost of the equipment. We propose a protocol for 222Rn measurement based on three simultaneous integrating radon detectors that may help estimate the proportion of indoor 222Rn derived from the water supply.
A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and presentation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.