The Image Biomarker Standardization Initiative validated consensus-based reference values for 169 radiomics features, thus enabling calibration and verification of radiomics software. Key results: • research teams found agreement for calculation of 169 radiomics features derived from a digital phantom and a human lung cancer on CT scan. • Of these 169 candidate radiomics features, good to excellent reproducibility was achieved for 167 radiomics features using MRI, 18F-FDG PET and CT images obtained in 51 patients with soft-tissue sarcoma.
Radiomic studies link quantitative imaging features to patient outcomes in an effort to personalise treatment in oncology. To be clinically useful, a radiomic feature must be robust to image processing steps, which has made robustness testing a necessity for many technical aspects of feature extraction. We assessed the stability of radiomic features to interpolation processing and categorised features based on stable, systematic, or unstable responses. Here, 18 F-fluorodeoxyglucose ( 18 F-FDG) PET images for 441 oesophageal cancer patients (split: testing = 353, validation = 88) were resampled to 6 isotropic voxel sizes (1.5 mm, 1.8 mm, 2.0 mm, 2.2 mm, 2.5 mm, 2.7 mm) and 141 features were extracted from each volume of interest (VOI). Features were categorised into four groups with two statistical tests. Feature reliability was analysed using an intraclass correlation coefficient (ICC) and patient ranking consistency was assessed using a Spearman’s rank correlation coefficient ( ρ ). We categorised 93 features robust and 6 limited robustness (stable responses), 34 potentially correctable (systematic responses), and 8 not robust (unstable responses). We developed a correction technique for features with potential systematic variation that used surface fits to link voxel size and percentage change in feature value. Twenty-nine potentially correctable features were re-categorised to robust for the validation dataset, after applying corrections defined by surface fits generated on the testing dataset. Furthermore, we found the choice of interpolation algorithm alone (spline vs trilinear) resulted in large variation in values for a number of features but the response categorisations remained constant. This study attempted to quantify the diverse response of radiomics features commonly found in 18 F-FDG PET clinical modelling to isotropic voxel size interpolation.
Aim Enhanced prognostic models are required to improve risk stratification of patients with esophageal cancer so treatment decisions can be optimised. The primary aim was to externally validate a published prognostic model incorporating PET image features. Transferability of the model was compared using only clinical variables. Methods This was a Transparent Reporting of a multivariate prediction model for Individual Prognosis Or Diagnosis (TRIPOD) type 3 study. The model was validated against patients treated with neoadjuvant chemoradiotherapy according to the Neoadjuvant chemoradiotherapy plus surgery versus surgery alone for esophageal or junctional cancer (CROSS) trial regimen using pre-and post-harmonised image features. The Kaplan-Meier method with log-rank significance tests assessed risk strata discrimination. A Cox proportional hazards model assessed model calibration. Primary outcome was overall survival (OS). Results Between 2010 and 2015, 449 patients were included in the development (n=302), internal validation (n=101) and external validation (n=46) cohorts. No statistically significant difference in OS between patient quartiles was demonstrated in prognostic models incorporating PET image features (X 2 =1.42, df=3, p=0.70) or exclusively clinical variables (age, disease stage and treatment; X 2 =1.19, df=3, p=0.75). The calibration slope β of both models was not significantly different from unity (p=0.29 and 0.29, respectively). Risk groups defined using only clinical variables suggested differences in OS, although these were not statistically significant (X 2 =0.71, df=2, p=0.70). Conclusion The prognostic model did not enable significant discrimination between the validation risk groups, but a second model with exclusively clinical variables suggested some transferable prognostic ability. PET harmonisation did not significantly change the results of model validation.
Objectives: To improve clinical lymph node staging (cN-stage) in esophageal adenocarcinoma by developing and externally validating three prediction models; one with clinical variables only, one with positron emission tomography (PET) radiomics only, and a combined clinical and radiomics model. Methods: Consecutive patients with fluorodeoxyglucose (FDG) avid tumours treated with neo-adjuvant therapy between 2010 and 2016 in two international centres (n = 130 and n = 60, respectively) were included. Four clinical variables (age, gender, clinical T-stage and tumour regression grade) and PET radiomics from the primary tumour were used for model development. Diagnostic accuracy, area under curve (AUC), discrimination and calibration were calculated for each model. The prognostic significance was also assessed. Results: The incidence of lymph node metastases was 58% in both cohorts. The AUCs of the clinical, radiomics and combined models were 0.79, 0.69 and 0.82 in the developmental cohort, and 0.65, 0.63 and 0.69 in the external validation cohort, with good calibration demonstrated. The AUC of current cN-stage in development and validation cohorts was 0.60 and 0.66, respectively. For overall survival, the combined clinical and radiomics model achieved the best discrimination performance in the external validation cohort (X2 = 6.08, df = 1, p = 0.01). Conclusion: Accurate diagnosis of lymph node metastases is crucial for prognosis and guiding treatment decisions. Despite finding improved predictive performance in the development cohort, the models using PET radiomics derived from the primary tumour were not fully replicated in an external validation cohort. Advances in knowledge: This international study attempted to externally validate a new prediction model for lymph node metastases using PET radiomics. A model combining clinical variables and PET radiomics improved discrimination of lymph node metastases, but these results were not externally replicated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.