A new method for proteolytic stable isotope labeling is introduced to provide quantitative and concurrent comparisons between individual proteins from two entire proteome pools or their subfractions. Two 18O atoms are incorporated universally into the carboxyl termini of all tryptic peptides during the proteolytic cleavage of all proteins in the first pool. Proteins in the second pool are cleaved analogously with the carboxyl termini of the resulting peptides containing two 16O atoms (i.e., no labeling). The two peptide mixtures are pooled for fractionation and separation, and the masses and isotope ratios of each peptide pair (differing by 4 Da) are measured by high-resolution mass spectrometry. Short sequences and/or accurate mass measurements combined with proteomics software tools allow the peptides to be related to the precursor proteins from which they are derived. Relative signal intensities of paired peptides quantify the expression levels of their precursor proteins from proteome pools to be compared, using an equation described in the paper. Observation of individual (unpaired) peptides is mainly interpreted as differential modification or sequence variation for the protein from the respective proteome pool. The method is evaluated here in a comparison of virion proteins for two serotypes (Ad5 and Ad2) of adenovirus, taking advantage of information already available about protein sequences and concentrations. In general, proteolytic 18O labeling enables a shotgun approach for proteomic studies with quantitation capability and is proposed as a useful tool for comparative proteomic studies of very complex protein mixtures.
The application of MALDI mass spectrometry to desorb protein biomarkers from intact viruses, bacteria, fungus, and spores is the focus of this review. Instrumentation, sample collection, sample preparation, and algorithms for data analysis are summarized. Optimally these analyses should be carried out in less than five minutes. Successful applications are discussed from biotechnology, cell biology, and the pharmaceutical industry.
A method for rapid identification of microorganisms is presented, which exploits the wealth of information contained in prokaryotic genome and protein sequence databases. The method is based on determining the masses of a set of ions by MALDI TOF mass spectrometry of intact or treated cells. Subsequent correlation of each ion in the set to a protein, along with the organismic source of the protein, is performed by searching an Internet-accessible protein database. Convoluting the lists for all ions and ranking the organisms corresponding to matched ions results in the identification of the microorganism. The method has been successfully demonstrated on B. subtilis and E. coli, two organisms with completely sequenced genomes. The method has been also tested for identification from mass spectra of mixtures of microorganisms, from spectra of an organism at different growth stages, and from spectra originating at other laboratories. Experimental factors such as MALDI matrix preparation, spectral reproducibility, contaminants, mass range, and measurement accuracy on the database search procedure are addressed too. The proposed method has several advantages over other MS methods for microorganism identification.
The equation (eq 1, page 2839) for calculation of ratio 1 should be "ratio 1 ). This correction has minimal effect on the values of ratio 1 in Table 1 (page 2839).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.