The use of electrical energy in the industrial is very important to drive production machines. Machine maintenance is carried out so that the lifetime of the machine becomes longer so that the production process continues. Temperature is one of the most common indicators of the structural health of equipment and components. This means that the main symptoms of damage to machines and equipment can be indicated by increasing the temperature of the equipment. One of the symptoms of an increase in equipment temperature is due to a loose cable termination. The use of infrared thermography to measure the temperature rise due to loose termination is one of the methods in electrical machine maintenance. Previous studies using infrared thermography to measure the temperature rise due to loose termination have been carried out by many researchers, but these studies did not show a correlation between the level of loose termination and the increase in temperature but only stated that the loose termination caused an increase in temperature. This study focuses on finding the relationship between the level of loose termination compared to standard torque and the increase in temperature at the termination point. This is very useful as a quick overview in determining the level of urgency in maintenance activity, that percentage of loose termination of a certain value below the standard will give an increase in temperature of a certain value as well. This study resulted, for the torque setting condition 67% below the standard (loose) the temperature increase at the terminal was 13.4% - 15.6%, for the torque setting condition 33% below the standard temperature increase at the terminal of 12.3% -13.8% which mean that the increase in temperature is directly proportional to the level of slack termination and is also directly proportional to the increase in the motor speed. If the termination torque level is lower and the motor speed is increased, the terminal temperature rise will be drastically rise.
This research builds a real time information system application for industry training. The system is built to support employee competency improvement through training schedule notification, attendance confirmation, monitoring of pre-test and posttest results. The design of the application is build using android studio, while the hardware using Arduino mega2560 and GSM module. SMS notification system transmitted by GSM module, utilizing AT Command. Experiments were conducted by testing the conformity of the results of notification delivery via SMS, confirmation of participation or attendance of training, monitoring of pre-test and post-test results on mobile phones. Sophistication is based on data contained in the sending system or online database and the receiving system or mobile phone. Based on the experiment, it was found that the system can deliver SMS notification according to schedule. Confirmation of attendance, monitoring of pre-test and post-test results conducted by trainee has been in accordance with online databases.
Visible Laser Light Communication System (VLLC) is a wireless communication system, using laser as the medium. In the data transfer process, it is possible to have optical interference where 2 laser beams coincide with one point on the reflector. Research on the effect of laser source interference has been carried out by several researchers including mitigation actions to reduce its effects. This experiment uses 2 optical distance sensors that produce a laser with a wavelength of 650 nm with a power <=4.1 mW and with the direction of the laser beam both of them cross each other. To determine the effect of the interference of two laser beams when crossing the communication process in the visible light communication system, a reflector is used which can capture the two laser beams and the reflector can be shifted gradually so that a condition can be obtained where the two laser beams meet at one point. From the measurements made at the points after the laser beam crossing, the measurements at the point where the beam crossed, and the measurements at the points before the beam crossing, it was obtained data, at the exact point where the laser beam crossed the interference occurred, which is indicated by unstable output voltage of the two lasers, so that communication at the point of intersection is disrupted. However, if outside the point of contact both before and after the point of contact, interference and communication systems will not occur.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.