β-Thalassemia hemoglobin E (β-thal/Hb E) is the commonest form of hemoglobinopathy in Thailand. Shortened red cell life span, rapid iron turnover and tissue deposition of excess iron are major factors responsible for functional and physiological abnormalities found in various forms of thalassemia. Increased deposition of iron had been found in renal parenchyma of thalassemic patients, but no systematic study of the effect of the deposits on renal functions has been available. The purpose of this study is to describe the functional abnormalities of the kidney in patients with β-thal/Hb E and provide evidence that increased oxidative stress might be one of the factors responsible for the damage. Urine and serum samples from 95 patients with β-thal/Hb E were studied comparing with 27 age-matched healthy controls. No difference in the creatinine clearance was observed. β-thal/Hb E patients excreted significantly more urinary protein (0.8 ± 0.5 vs. 0.3±0.1 g/day, p < 0.001). Aminoaciduria was found in 16% of the patients. Analysis of urinary protein by SDS-PAGE electrophoresis and silver staining revealed abnormal pattern of protein with increased small molecular weight (<45 kD) bands. Morning urine analysis showed significant lower urine osmolality (578.3 ± 164.6 vs. 762.4 ± 169.9 mosm/kg, p < 0.001) in patients. Patients excreted more NAG (N-acetyl beta-D-glucosaminidase, 26.3 ± 41.3 vs. 8.4 ± 3.9 U/g Cr, p < 0.0001) and β2-microglobulin, 124.3 ± 167 vs. 71 ± 65.5 µg/g Cr, p = 0.001. Plasma and urine MDA (malonyldialdehyde) levels were both raised (p < 0.0001). Nine patients were selected for renal acidification study. All were found to be normal, but showed poor response to DDAVP challenge (urine osmolality 533 ± 71). This is the first report of renal tubular defects found associated with β-thal/Hb E disease. The mechanism leading to the damage is not known but it might be related to increased oxidative stress secondary to tissue deposition of iron, as indicated by the raised levels of serum and urine MDA. It is not known whether these functional defects would have any long-term effects on the patients. Further studies are warranted and means of prevention of these defects should urgently be sought.
Methods facilitating research in malaria are of pivotal relevance. Flow cytometry offers the possibility of rapid enumeration of parasitemia. It relies on staining the parasite DNA to distinguish between infected and non-infected red blood cell (RBC) populations. Unfortunately, in rodents abundant reticulocyte RNA interferes with the application of the method. This results in time-consuming sample preparation protocols that offer no clear advantage over microscopic counting. We re-evaluated the use of the DNA/RNA discriminating vital fluorochrome acridine orange (AO) for rapid flow cytometric enumeration of parasitemia in rodents. Whole blood from rodents infected with Plasmodium berghei and Plasmodium yoelii was stained with AO and analyzed by flow cytometer. A newly developed two-channel (FL1/FL3) detection method was compared with conventional one-channel (FL1) detection and microscopic counting. The new AO two-channel detection method clearly discriminated between infected and non-infected RBC populations. It showed to be linear above parasitemias of 0.3%. Sample processing time amounted to approximately 5 min. It is shown that AO can be used for rapid, precise, and accurate enumeration of parasitemia in rodents. Due to its ease of handling the method might find widespread application in malaria research.
BackgroundHighly purified infected red blood cells (irbc), or highly synchronized parasite cultures, are regularly required in malaria research. Conventional isolation and synchronization rely on density and osmotic fragility of irbc, respectively. High gradient magnetic separation (HGMS) offers an alternative based on intrinsic magnetic properties of irbc, avoiding exposure to chemicals and osmotic stress. Successful HGMS concentration in malaria research was previously reported using polymer coated columns, while HGMS depletion has not been described yet. This study presents a new approach to both HGMS concentration and depletion in malaria research, rendering polymer coating unnecessary.MethodsA dipole magnet generating a strong homogenous field was custom assembled. Polypropylene syringes were fitted with one-way stopcocks and filled with stainless steel wool. Rbc from Plasmodium falciparum cultures were resuspended in density and viscosity optimized HGMS buffers and HGMS processed. Purification and depletion results were analysed by flow cytometer and light microscopy. Viability was evaluated by calculating the infection rate after re-culturing of isolates.ResultsIn HGMS concentration, purity of irbc isolates from asynchronous cultures consistently ranged from 94.8% to 98.4% (mean 95.7%). With further optimization, over 90% of isolated irbc contained segmented schizonts. Processing time was less than 45 min. Reinfection rates ranged from 21.0% to 56.4%. In HGMS depletion, results were comparable to treatment with sorbitol, as demonstrated by essentially identical development of cultures.ConclusionThe novel HGMS concentration procedure achieves high purities of segmented stage irbc from standard asynchronous cultures, and is the first HGMS depletion alternative to sorbitol lysis. It represents a simple and highly efficient alternative to conventional irbc concentration and synchronization methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.