Permanent HBP was feasible and safe in a large real-world population requiring permanent pacemakers. His bundle pacing was associated with reduction in the combined endpoint of death, HFH, or upgrade to BiVP compared to RVP in patients requiring permanent pacemakers.
BACKGROUND His bundle pacing (HBP) is the most physiologic form of pacing but associated with higher thresholds and lower success in patients with His-Purkinje conduction disease. Recent reports have described transvenous left bundle branch area pacing (LBBAP). OBJECTIVE We aimed to prospectively evaluate the feasibility and the electrophysiologic and echocardiographic characteristics of LBBAP. METHODS Patients requiring pacing for bradycardia or heart failure indications (failed left ventricular [LV] lead) were prospectively enrolled. LBBAP was performed with a Medtronic 3830 lead. Presence of left bundle branch (LBB) potential, paced QRS morphology/duration, and peak LV activation time (pLVAT) were recorded at implant. Pacing threshold and sensing was assessed at implant and follow-up. Echocardiography was performed to assess the approximate lead location and impact on tricuspid valve function. RESULTS LBBAP was successful in 93 of 100 (93%) patients. Mean age was 75 6 13 years; men 69%, left bundle branch block 24%, right bundle branch block 25%, intraventricular conduction defect 8%. Indications for pacing were atrioventricular (AV) block 54%, sinus node dysfunction 23%, AV node ablation 7%, cardiac resynchronization therapy 11%, HBP lead failure 7%. Baseline QRS duration was 133 6 35 ms. Paced QRS duration was 136 6 17 ms. LBB potentials were observed in 63 patients with left bundle branch-ventricle (LBB-V) interval of 27 6 6 ms. pLVAT was 75 6 16 ms. Pacing threshold at implant was 0.6 6 0.4 V @ 0.5 ms and R waves were 10 6 6 mV and remained stable at median follow-up of 3 months. The lead depth in the septum was approximately 1.4 6 0.23 cm. CONCLUSIONS LBBAP was feasible in a high percentage of patients with low thresholds during acute follow-up. HBP and LBBAP may significantly increase the overall success of physiologic pacing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.