Biochemical oxygen demand (BOD) is a widely used index of water quality in wastewater treatment; however, conventional measurement methods are time-consuming. In this study, we analyzed a novel flame-oxidized stainless steel anode (FO-SSA) for use as the probe of bioelectrochemical system (BES)-based biosensors to monitor the BOD of treated swine wastewater. A thinner biofilm formed on the FO-SSA compared with that on a common carbon-cloth anode (CCA). The FO-SSA was superior to the CCA in terms of rapid sensing; the response time of the FO-SSA to obtain the value of R2 > 0.8 was 1 h, whereas the CCA required 4 h. These results indicate that the FO-SSA offers better performance than traditional CCAs in BES biosensors and can be used to improve biomonitoring of wastewater.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.