The purpose of this work is to assess eight detectors performance for output factor (OF), percent depth dose (PDD), and beam profiles in a 6‐MV Clinac stereotactic radiosurgery mode for cone irradiation using Monte Carlo simulation as reference. Cones with diameters comprised between 30 and 4 mm have been studied. The evaluated detectors were ionization chambers: pinpoint and pinpoint 3D, diodes: SRS, P and E, Edge, MicroDiamond and EBT3 radiochromic films. The results showed that pinpoints underestimate OF up to −2.3% for cone diameters ≥10 mm and down to −12% for smaller cones. Both nonshielded (SRS and E) and shielded diodes (P and Edge) overestimate the OF respectively up to 3.3% and 5.2% for cone diameters ≥10 mm and in both cases more than 7% for smaller cones. MicroDiamond slightly overestimates the OF, 3.7% for all the cones and EBT3 film is the closest to Monte Carlo with maximum difference of ±1% whatever the cone size is. For the profiles and the PDD, particularly for the small cones, the size of the detector predominates. All diodes and EBT3 agree with the simulation within ±0.2 mm for beam profiles determination. For PDD curve all the active detectors response agree with simulation up to 1% for all the cones. EBT3 is the more accurate detector for beam profiles and OF determinations of stereotactic cones but it is restrictive to use. Due to respectively inappropriate size of the sensitive volume and composition, pinpoints and diodes do not seem appropriate without OF corrective factors below 10 mm diameter cone. MicroDiamond appears to be the best detector for OF determination regardless all cones. For off‐axis measurements, the size of the detector predominates and for PDD all detectors give promising results.
The chemokine receptors CXCR1/2 play a key role in the aggressiveness of several types of cancers including head and neck squamous cell carcinomas (HNSCCs). In HNSCCs, CXCR1/2 signaling promotes cell proliferation and angiogenesis leading to tumor growth and metastasis. The competitive inhibitor of CXCR1/2, C29, inhibits the growth of experimental HNSCCs in mice. However, a non-invasive tool to monitor treatment response is essential to implement the use of C29 in clinical practices.
18
F-FDG PET/CT is a gold-standard tool for the staging and the post-therapy follow-up of HNSCCs patients. Our study aimed to perform the first i
n vivo
monitoring of C29 efficacy by non-invasive
18
F-FDG PET/CT imaging. Mice bearing experimental HNSCCs (CAL33) were injected with
18
F-FDG (T0) and thereafter treated (n = 7 mice, 9 tumors, 50 mg/kg by gavage) or not (n = 7 mice, 10 tumors) with C29 for 4 consecutive days. Final
18
F-FDG-tumor uptake was determined at day 4 (TF). The average relative change (TF-T0) in
18
F-FDG tumor uptake was +25.85 ± 10.93 % in the control group
vs
−5.72 ± 10.07 % in the C29-treated group (p < 0.01). These results were consistent with the decrease of the tumor burden and with the decrease of tumor proliferating Ki67+ cells. These results paved the way for the use of
18
F-FDG to monitor tumor response following C29 treatment.
Purpose
The main objective of this study was to evaluate the ability of a large field Cadmium Zinc Telluride (CZT) camera to estimate thyroid uptake (TU) on single photon emission computed tomography (SPECT) images with and without attenuation correction (Tomo-AC and Tomo-NoAC) compared with Planar acquisition in a series of 23 consecutive patients. The secondary objective was to determine radiation doses for the tracer administration and for the additional Computed Tomography (CT) scan.
Methods
Cross-calibration factors were determined using a thyroid phantom, for Planar, Tomo-AC and Tomo-NoAC images. Then Planar and SPECT/CT acquisitions centered on the thyroid were performed on 5 anthropomorphic phantoms with activity ranging from 0.4 to 10 MBq, and 23 patients after administration of 79.2 ± 3.7 MBq of [99mTc]-pertechnetate. We estimated the absolute thyroid activity (AThA) for the anthropomorphic phantoms and the TU for the patients. Radiation dose was also determined using International Commission on Radiological Protection (ICRP) reports and VirtualDoseTMCT software.
Results
Cross-calibration factors were 66.2 ± 4.9, 60.7 ± 0.7 and 26.5 ± 0.3 counts/(MBq s), respectively, for Planar, Tomo-AC and Tomo-NoAC images. Theoretical and estimated AThA for Planar, Tomo-AC and Tomo-NoAC images were statistically highly correlated (r < 0.99; P < 10–4) and the average of the relative percentage difference between theoretical and estimated AThA were (8.6 ± 17.8), (− 1.3 ± 5.2) and (12.8 ± 5.7) %, respectively. Comparisons between TU based on different pairs of images (Planar vs Tomo-AC, Planar vs Tomo-NoAC and Tomo-AC vs Tomo-NoAC) showed statistically significant correlation (r = 0.972, 0.961 and 0.935, respectively; P < 10–3). Effective and thyroid absorbed doses were, respectively (0.34CT + 0.95NM) mSv, and (3.88CT + 1.74NM) mGy.
Conclusion
AThA estimation using Planar and SPECT/CT acquisitions on a new generation of CZT large-field cameras is feasible. In addition, TU on SPECT/CT was as accurate as conventional planar acquisition, but the CT induced additional thyroid exposure.
Trial registration Name of the registry: Thyroid Uptake Quantification on a New Generation of Gamma Camera (QUANTHYC). Trial number: NCT05049551. Registered September 20, 2021—Retrospectively registered, https://clinicaltrials.gov/ct2/show/record/NCT05049551?cntry=MC&draw=2&rank=4.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.