The influence of viewing time on the detectability of subtle and obvious lung cancers was studied. Frontal chest radiographs of 40 patients with subtle cancers, 40 patients with obvious cancers, and 40 healthy control subjects were shown to four observers for four different viewing times (0.25 second, 1 second, 4 seconds, and unlimited time). Receiver operating characteristic analysis was used to compare the detectability of lesions. Performance was degraded as viewing time decreased. The true-positive fractions for subtle and obvious cancers were 30% and 70% at 0.25 second and 74% and 98% at unlimited viewing time, respectively, for a given false-positive fraction of 20%. Thus, even with unlimited viewing time, the false-negative fraction for subtle cancers was 26%. The difference in detectability between subtle and obvious lung cancers was exaggerated at 1.0 second compared with 4 seconds and unlimited viewing time. The following conclusions were reached: (a) a substantial proportion of subtle lung lesions are missed, even with unlimited viewing time; (b) a large proportion of obvious lung cancers are detected with flash viewing; (c) the detectability of lesions decreases considerably as viewing time becomes less than 4 seconds; and (d) differences in detectability are exaggerated by short viewing times.
The ability to accurately diagnose mediastinal lymph node involvement is significantly important in patients with nonsmall cell lung cancer (NSCLC). Positron emission tomography (PET) imaging has become a standard technique to assess lymph node involvement in patients with NSCLC. The purpose of this study is to evaluate the accuracy of PET scan imaging as a mediastinal staging tool in patients with NSCLC at our regional teaching institution. We performed a single-institution, retrospective review of patients diagnosed with NSCLC from January 1, 2006, through December 31, 2007. We included only those patients who underwent computed tomography (CT), PET, and pathologic assessment of mediastinal lymph nodes. Using pathologic assessment as the criterion standard, the overall accuracy, sensitivity, specificity, and positive and negative predictive values of CT and PET were calculated. One hundred seventeen patients were identified for inclusion in the study. The overall accuracy was 81.2 per cent for CT and 91.5 per cent for PET. Sensitivity was 42.1 per cent for CT and 52.6 per cent for PET. Specificity was 88.8 per cent for CT and 99.0 per cent for PET. Positive predictive values were 42.1 per cent for CT and 90.9 per cent for PET; negative predictive values were 88.8 per cent for CT and 91.5 per cent for PET. False-negative result rates were 9.4 per cent for CT and 7.7 per cent for PET; false-positive result rates were 9.4 per cent for CT and 0.9 per cent for PET. Our analysis confirms the use of PET scan imaging in the staging of patients with NSCLC at a regional teaching institution.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.