In order to support the operation of ITER and the planned experimental programme an extensive set of plasma and first wall measurements will be required. The number and type of required measurements will be similar to those made on the present-day large tokamaks while the specification of the measurements-time and spatial resolutions, etc-will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements.The implementation of diagnostic systems on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required.The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all the plasma parameters needed to support the basic and advanced operation (including active control) of the device, machine protection and also those needed to support the physics programme. Once the requirements are defined, the appropriate (combination of) diagnostic techniques can be selected and their implementation onto the tokamak can be developed. The selected list of diagnostics is an important guideline for identifying dedicated research and development needs in the area of ITER diagnostics.This paper gives a comprehensive overview of recent progress in the field of ITER diagnostics with emphasis on the implementation issues. After a discussion of the measurement requirements for plasma parameters in ITER and their justifications, recent progress in the field of diagnostics to measure a selected set of plasma parameters is presented. The integration of the various diagnostic systems onto the ITER tokamak is described. Generic research and development in the field of irradiation effects on materials and environmental effects on first mirrors are briefly presented. The paper ends with an assessment of the measurement capability for ITER and a forward of what will be gained from operation of the various diagnostic systems on ITER in preparation for the machines that will follow ITER. Performance assessment relative to requirements Design meets requirements S339 A.J.H. Donné et alPhysics Basis [7] and remains essentially the same. However, for ITER, the specific limits have changed. 2.1.2.Measurements needed for plasma control and evaluation. The measurements needed for plasma control and evaluation are naturally directly linked to the experimental programme, and particularly to the operating phase (i.e. H, D or D/T) and the operating scenario (H-mode, hybrid, etc). Since there is expected to be a phased introduction of po...
The spatial structure of toroidal Alfvén eigenmodes and reversed shear Alfvén eigenmodes in DIII-D is obtained from electron-cyclotron-emission measurements. Peak measured temperature perturbations are of similar magnitude for both toroidal Alfvén eigenmodes and reversed shear Alfvén eigenmodes and found to be deltaT(e)/T(e) approximately equal to 0.5%. Simultaneous measurements of density fluctuations using beam-emission spectroscopy indicate deltan(e)/n(e) approximately equal to 0.25%. Predictions of the measured temperature and density perturbation profiles as well as deltaT(e)/deltan(e) from the ideal magnetohydrodynamic code NOVA are in close agreement with experiment.
Double transport barrier plasmas comprised of an edge enhanced D α (EDA) H-mode pedestal and an internal transport barrier (ITB) have been observed in Alcator C-Mod. The ITB can be routinely produced in ICRF heated plasmas by locating the wave resonance off-axis near |r/a| ∼ 0.5, provided the target plasma average density is above ∼1.4 × 10 20 /m 3 , and can develop spontaneously in some Ohmic H-mode discharges. The formation of the barrier appears in conjunction with a decrease or reversal in the central (impurity) toroidal rotation velocity. The ITB foot is located near r/a = 0.5, regardless of how the barrier was produced. The ITBs can persist for ∼15 energy confinement times (τ E), but exhibit a continuous increase of the central electron density, up to values near 1×10 21 /m 3 (in the absence of an internal particle source), followed by collapse of the barrier. This barrier is also evident in the ion temperature profiles, and a significant drop of the core thermal conductivity, χ eff , when the barrier forms is confirmed by modeling. Application of additional on-axis ICRF heating arrests the density and impurity peaking, which occurs along with an increase (co-current) in the core rotation velocity. Steady state double barrier plasmas have been maintained for 10 τ E or longer, with n/n GW ∼ 0.75 and with a bootstrap fraction of 0.13 near the ITB foot. The trigger mechanism for the ITB formation is presently not understood.
A detailed comparison between the observed and expected loss of alpha-like MeV fusion products in TFTR is presented. The D-D fusion products (mainly the 1 MeV triton) were measured with an 2-D imaging scintillation detector. The expected first-orbit loss was calculated with a simple Lorentz orbit code. In almost all cases the measured loss was consistent with the expected first-orbit loss model. Exceptions are noted for small major radius plasmas and during strong MHD activity.
Beam Emission Spectroscopy (BES), a high-sensitivity, good spatial resolution imaging diagnostic system, has been deployed and recently upgraded and expanded at the DIII-D tokamak to better understand density fluctuations arising from plasma turbulence. The currently deployed system images density fluctuations over an approximately 5 × 7 cm region at the plasma mid-plane (radially scannable over 0.2 < r/a ≤ 1) with a 5 × 6 (radial × poloidal) grid of rectangular detection channels, with one microsecond time resolution. BES observes collisionally-induced, Doppler-shifted D α fluorescence (λ = 652-655 nm) of injected deuterium neutral beam atoms. The diagnostic wavenumber sensitivity is approximately k ⊥ < 2.5 cm −1 , allowing measurement of longwavelength (k ⊥ ρ I < 1) density fluctuations. The recent upgrade includes expanded fiber optics bundles, customdesigned high-transmission, sharp-edge interference filters, ultra fast collection optics, and enlarged photodiode detectors that together provide nearly an order of magnitude increase in sensitivity relative to an earlier generation BES system. The high sensitivity allows visualization of turbulence at normalized density fluctuation amplitudes ofn/n < 1%, typical of fluctuation levels in the core region. The imaging array allows for sampling over 2-3 turbulent eddy scale lengths, which captures the essential dynamics of eddy evolution, interaction and shearing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.