Abstract. We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a ∼ 5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4×10 −3 counts per hour in the energy region-of-interest and signal spot area.
In this work, we monitor the onset of nonthermal melting in single-crystal silicon by implementing an x-ray pump-x-ray probe scheme. Using the ultrashort pulses provided by the Linac Coherent Light Source (SLAC) and a custom-built split-and-delay line for hard x rays, we achieve the temporal resolution needed to detect the onset of the transition. Our data show no loss of long-range order up to 150±40 fs from photoabsorption, which we interpret as the time needed for the electronic system to equilibrate at or above the critical nonthermal melting temperature. Once such equilibration is reached, the loss of long-range atomic order proceeds inertially and is completed within 315±40 fs from photoabsorption.
We report a summary ofthe surface damage, growth mitigation effort at 3w for fused silica optics at LLNL. The objective was to experimentally validate selected methods that could be applied to pre-initiated or retrieved-fromservice optics, to stop further damage growth. A specific goal was to obtain sufficient data and information on successful methods for fused silica optics to select a single approach for processing NIF optics.This paper includes the test results and the evaluation thereof, for several mitigation methods for fused silica. The mitigation methods tested in this study are wet chemical etching, cold plasma etching, CO2 laser processing, and micro-flame torch processing. We found that CO2 laser processing produces the most significant and consistent results to halt laser-induced surface damage growth on fused silica. We recorded successful mitigation of the growth of laser-induced surface damage sites as large as 0.5mm diameter, for 1000 shots at fluences in the range of 8 to 1 3J/cm2. We obtained sufficient data for elimination of damage growth using CO2 laser processing on subaperture representative optics, to proceed with application to full-scale NIF optics.
Significant effort currently is being devoted to the development of noninvasive imaging systems that allow in vivo assessment of biological and biomolecular interactions in mice and other small animals. While physiological function in small animals can be localized and imaged using conventional radionuclide imaging techniques such as single-photon emission tomography (SPECT) and positron emission tomography (PET), these techniques inherently are limited to spatial resolutions of 1−2 mm. For this reason, we are developing a small animal radionuclide imaging system (SARIS) using grazing incidence optics to focus gamma-rays emitted by 125 I and other radiopharmaceuticals. We have developed a prototype optic with sufficient accuracy and precision to focus the 27.5 keV photons from 125 I onto a high-resolution imaging detector. Experimental measurements from the prototype have demonstrated that the optic can focus X-rays from a microfocus X-ray tube to a spot having physical dimensions (approximately 1500 microns half-power diameter) consistent with those predicted by theory. Our theoretical and numerical analysis also indicate that an optic can be designed and build that ultimately can achieve 100 µm spatial resolution with sufficient efficiency to perform in vivo single photon emission imaging studies in small animal.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.