Constant rapid pacing may suppress arrhythmias, but it is usually poorly tolerated in the long term. We report a pilot study of a new pacing algorithm for overdrive suppression of atrial premature complexes (APCs) and atrial fibrillation (AF), which prevents postextrasystolic pauses and varies the pacing rate in response to the frequency of APCs. The algorithm was tested in a multiple crossover study for 24 hours in dual chamber pacemakers implanted in 70 patients. Comparison was made on ambulatory recordings between the number of atrial arrhythmias commencing with the algorithm active and inactive. In all cases, the algorithm functioned as designed. No patient was aware of its operation, and no malignant arrhythmias were induced. The 36 recordings that showed atrial arrhythmia were included for analysis. The effects of the algorithm were: APCs (estimated from pacemaker statistics) reduced in 18 patients, increased in 8 (P = 0.02); atrial salvos reduced in 12, increased in 4 (P = 0.041); and AF reduced in 11, increased in 8 (P = NS). In all patients with frequent AF (> 5 episodes in total), fewer episodes occurred when the algorithm was active. We conclude that the algorithm is safe and well tolerated, reduces atrial ectopic activity, and may reduce the frequency of sustained atrial fibrillation.
The lack of specificity of VT detection is a significant shortcoming of current ICDs. In a French multicenter study, 18 patients underwent implantation of the Defender 9001 (ELA Medical), an ICD utilizing dual chamber pacing and arrhythmia detection. Over a mean follow-up period of 7.1 +/- 4.5 months, 176 tachycardia episodes recorded in the device memory were analyzed, and physician diagnosis was compared with that by the device. All 122 VT/VF episodes were correctly diagnosed, as were 51 of 53 supraventricular tachyarrhythmias. Two episodes of AF with rapid regular ventricular rates were treated as VT, and a third episode, treated as VT, could not be diagnosed with certainty. A dual chamber pacemaker defibrillator offers improved diagnostic specificity without loss of sensitivity, in addition to the hemodynamic benefit of dual chamber pacing.
In this conventional ICD population, the overall specificity of standard dual-chamber arrhythmia detection settings reached 94%. This feature allows efficient detection of fast as well as slow VT events with a very low rate of inappropriate shocks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.