The most common methods for measuring digoxin concentrations in serum are immunoassays. The prerequisite for exact determination of the digoxin value is an antibody that specifically binds digoxin. Because digitoxin differs from digoxin only in the C-12 hydroxy group, it is difficult to obtain anti-digoxin antibodies that do not cross-react with this compound. During the development of a fluorescence polarization immunoassay (FPIA) for digoxin, we investigated digoxin tracers with different structures. We found that in FPIA the digitoxin cross-reactivity of an antibody could be reduced by varying the structure of the tracer molecule.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.