SummaryEndovascular procedures are commonly used for treatment of vascular pathologies. These interventions are routinely performed under angiographic control. Angioplasty is increasingly more often used for correction of dialysis fistula – especially dilatation of stenosis. We describe the technique of dialysis fistula angioplasty under ultrasound control. Benefits of this procedure include lack of nephrotoxic contrast, what is especially important in chronic kidney disease patients in pre-dialysis period. Advantages of ultrasound guidance during dialysis fistula angioplasty lead to cause more and more frequent employment of this technique.
Background: The management of patent dialysis fistulas in patients after kidney transplantation (KTx) is controversial—the options that are usually considered are the fistula’s closure or observation. Many complications of dialysis fistulas occur in patients after KTx, and immunosuppression increases the risk of fistula aneurysms and hyperkinetic flow. This study aimed to evaluate the results of dialysis fistula aneurysm treatment in patients after KTx and to compare them to procedures performed in an end-stage renal disease (ESRD) dialyzed population. Methods: We enrolled 83 renal transplant recipients and 123 ESRD patients with dialysis fistula aneurysms qualified for surgical revision to this single-center, prospective study. The results of the surgical treatment of dialysis fistula aneurysms were analyzed, and the primary, assisted primary and secondary patency rate, percentage and type of complications were also assessed. Results: For the treatment of dialysis fistula aneurysms in transplant patients, we performed dialysis fistula excisions with fistula closure in 50 patients (60.2%), excision with primary fistula reconstruction (n = 10, 12.0%) or excision with PTFE bypasses (n = 23, 27.7%). Postoperative complications occurred in 11 patients (13.3%) during a follow-up (median follow-up, 36 months), mostly in distant periods (median time after correction procedure, 11.7 months). The most common complication was outflow stenosis, followed by hematoma, dialysis fistula thrombosis and the formation of a new aneurysm and postoperative bleeding, infection and lymphocele. The 12-month primary, primary assisted and secondary patency rates of fistulas corrected by aneurysm excision and primary reconstruction in the KTx group were all 100%; in the control ESRD group, the 12-month primary rate was 70%, and the primary assisted and secondary patency rates were 100%. The 12-month primary, primarily assisted and secondary patency rates after dialysis fistula aneurysm excision combined with PTFE bypass were better in the KTx group than in the control ESRD group (85% vs. 71.8%, 90% vs. 84.5% and 95% vs. 91.7%, respectively). Kaplan–Meier analysis showed a significant difference in primary patency (p = 0.018) and assisted primary (p = 0.018) rates and a strong tendency in secondary patency rates (p = 0.053) between the KTx and ESRD groups after dialysis fistula excisions combined with PTFE bypass. No statistically significant differences in patency rates between fistulas treated by primary reconstruction and reconstructed with PTFE bypass were observed in KTx patients. Conclusions: Reconstructions of dialysis fistula aneurysms give good long-term results, with a low risk of complications. The reconstruction of dialysis fistulas can be an effective treatment method. Thus, this is an attractive option in addition to fistula ligation or observation in patients after KTx. Reconstructions of dialysis fistula aneurysms enable the preservation of the dialysis fistula while reducing various complications.
Introduction: Dialysis fistula aneurysms are common complications, which require surgical revision in selective cases. The results of aneurysm excision with arteriovenous anastomosis proximalization for the treatment of dialysis fistula aneurysms have been described below. Methods: Patients qualified for the reconstruction of a dialysis fistula aneurysm underwent a duplex ultrasound examination. The diameter, length of the aneurysm, relations with the artery, thrombus presence and blood flow were determined. In the case of favorable anatomical conditions, we performed aneurysm excision with arteriovenous anastomosis proximalization as the procedure of choice. Patients, dialysis access, operative data and the results obtained during a median follow-up of 41 months were then analyzed. Findings: Since 2012, we have performed 20 aneurysm excision combined with primary anastomosis as dialysis fistula aneurysm treatment. In 18 patients, aneurysm excision was combined with simple re-anastomosis in the more proximal arterial segment. In 2 autogenous radio-cephalic forearm direct fistulas the aneurysm excision was combined with switching anastomosis type from side-to-end to end-to-end. The 12- and 24-month primary patency rates of corrected fistulas in the observed group were 94.7% and 82.4%, respectively. No early complications were noted. In 7 patients (35%) we observed late complications, which required reintervention or led to access failure. Dialysis fistula thrombosis as an indication for treatment was a significant risk factor for late re-occlusion. Discussion: A simple primary reconstruction by arteriovenous anastomosis proximalization and aneurysm excision for the surgical correction of dialysis fistula aneurysms has potential benefits compared to established methods—aneurysmorraphy and aneurysm excision with a vascular prosthesis bypass. The obtained data showed the efficiency, safety and excellent long-term results of this procedure.
Objectives Dialysis fistula aneurysms are common complications which in selective cases require surgical revision. It is recommended to detect and treat outflow stenosis concurrent with a dialysis fistula aneurysm, but usually, the treatment is divided into two stages – the open and endovascular stages are performed separately. We describe the results of hybrid procedures composed of aneurysm resection and endovascular correction for outflow veins performed for a dialysis fistula aneurysm treatment. Methods From March 2012, we performed hybrid procedures in 28 patients to correct dialysis fistula aneurysms. Patients, dialysis access, operative data, and the results obtained during a median follow-up of 28.5 months were analyzed. Results For dialysis fistula aneurysm correction, we performed 27 bypasses and 1 aneurysmorraphy. For outflow vein stenosis correction, we performed standard balloon angioplasty, no stents or stentgraft were used. The average increase in minimal diameter after angioplasty was 135.5% (range 57–275%). The 12- and 24-month primary patency rates of corrected fistulas in the observed group were 92.3% and 80%, respectively. A significant difference in the one-year patency rates between the urgent and planned procedures was observed (81.2% vs. 100%, respectively). No early complications related to endovascular or open procedures were observed. Late complications were observed in seven patients (25%) – mainly thrombosis caused by the recurrence of outflow vein stenosis (six patients, 21.5%), infection, lymphocele, and hematoma (one case of each complication). Conclusions A hybrid procedure for the surgical correction of dialysis fistula aneurysms with the simultaneous correction of outflow pathologies enables effective long-term treatment. The obtained data showed the efficiency and good results of this procedure. Procedures performed for urgent indications significantly increase the risk for later complications, especially fistula thrombosis and loss of dialysis access.
IntroductionPercutaneous endovascular angioplasty has become the treatment of choice for dialysis fistula stenosis. The ultrasound-guided endovascular procedure is used in patients with severe renal impairment and advanced renal transplant failure, when the need for nephrotoxic contrast administration in standard angioplasty may worsen renal function.AimTo evaluate endovascular angioplasty guided by ultrasound for dialysis fistula stenosis in renal transplant patients with severe graft insufficiency.Material and methodsWe compared ultrasound (US)-guided angioplasty, performed in patients after renal transplantation, with standard contrast angioplasty performed in dialysis patients. We treated 10 kidney allograft recipients (9 kidneys and 1 kidney-pancreas) with significantly compromised renal transplant function and significant stenosis in dialysis fistulas, as detected during US examination. Patients were qualified for percutaneous angioplasty under US guidance. The mean period from transplantation was 32.7 months (5–100 months). Results of their treatment were compared to the control group of 20 end-stage renal disease patients with dialysis fistula stenosis treated by angioplasty under standard contrast visualization.ResultsThe immediate effectiveness of the angioplasty was 100% in both groups. No early complications of angioplasty or problems with the guidewire crossing the stenosis were observed. Twelve months of primary patency was observed in 80% and 45% in the US-guided and control groups, respectively.ConclusionsThe US-guided endovascular procedure is an effective and safe method of treating dialysis fistula stenosis in patients with impaired renal transplant function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.