A capillary gas chromatography method using a flame ionization detector has been developed for the trace analysis of allylamine (AA) in sevelamer hydrochloride (SVH) and sevelamer carbonate (SVC) drug substances. The method utilized a mega bore capillary column DB-CAM (30 m × 0.53 mm × 1.0 μm) with a bonded and cross-linked, base-deactivated polyethylene glycol stationary phase and was validated for specificity, sensitivity, precision, linearity, and accuracy. The detection and quantitation limits obtained for allylamine were 2 μg/g and 6 μg/g, respectively. The method was found to be linear in the range between 6 μg/g and 148 μg/g with a correlation coefficient of 0.9990. The average recoveries obtained in SVH and SVC were 93.9% and 99.1%, respectively. The developed method was found to be robust for the determination of AA in sevelamer drug substances and also the specificity was demonstrated with a gas chromatograph coupled with a mass spectrometer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.