The present study proposes a hybrid brain-computer interface (BCI) with 64 selectable items based on the fusion of P300 and steady-state visually evoked potential (SSVEP) brain signals. With this approach, row/column (RC) P300 and two-step SSVEP paradigms were integrated to create two hybrid paradigms, which we denote as the double RC (DRC) and 4-D spellers. In each hybrid paradigm, the target is simultaneously detected based on both P300 and SSVEP potentials as measured by the electroencephalogram. We further proposed a maximum-probability estimation (MPE) fusion approach to combine the P300 and SSVEP on a score level and compared this approach to other approaches based on linear discriminant analysis, a naïve Bayes classifier, and support vector machines. The experimental results obtained from thirteen participants indicated that the 4-D hybrid paradigm outperformed the DRC paradigm and that the MPE fusion achieved higher accuracy compared with the other approaches. Importantly, 12 of the 13 participants, using the 4-D paradigm achieved an accuracy of over 90% and the average accuracy was 95.18%. These promising results suggest that the proposed hybrid BCI system could be used in the design of a high-performance BCI-based keyboard.
The start of the cue is often used to initiate the feature window used to control motor imagery (MI)-based brain-computer interface (BCI) systems. However, the time latency during an MI period varies between trials for each participant. Fixing the starting time point of MI features can lead to decreased system performance in MI-based BCI systems. To address this issue, we propose a novel correlation-based time window selection (CTWS) algorithm for MI-based BCIs. Specifically, the optimized reference signals for each class were selected based on correlation analysis and performance evaluation. Furthermore, the starting points of time windows for both training and testing samples were adjusted using correlation analysis. Finally, the feature extraction and classification algorithms were used to calculate the classification accuracy. With two datasets, the results demonstrate that the CTWS algorithm significantly improved the system performance when compared to directly using feature extraction approaches. Importantly, the average improvement in accuracy of the CTWS algorithm on the datasets of healthy participants and stroke patients was 16.72% and 5.24%, respectively when compared to traditional common spatial pattern (CSP) algorithm. In addition, the average accuracy increased 7.36% and 9.29%, respectively when the CTWS was used in conjunction with Sub-Alpha-Beta Log-Det Divergences (Sub-ABLD) algorithm. These findings suggest that the proposed CTWS algorithm holds promise as a general feature extraction approach for MI-based BCIs.
Most P300 event-related potential (ERP)-based brain-computer interface (BCI) studies focus on gaze shift-dependent BCIs, which cannot be used by people who have lost voluntary eye movement. However, the performance of visual saccade-independent P300 BCIs is generally poor. To improve saccade-independent BCI performance, we propose a bimodal P300 BCI approach that simultaneously employs auditory and tactile stimuli. The proposed P300 BCI is a vision-independent system because no visual interaction is required of the user. Specifically, we designed a direction-congruent bimodal paradigm by randomly and simultaneously presenting auditory and tactile stimuli from the same direction. Furthermore, the channels and number of trials were tailored to each user to improve online performance. With 12 participants, the average online information transfer rate (ITR) of the bimodal approach improved by 45.43% and 51.05% over that attained, respectively, with the auditory and tactile approaches individually. Importantly, the average online ITR of the bimodal approach, including the break time between selections, reached 10.77 bits/min. These findings suggest that the proposed bimodal system holds promise as a practical visual saccade-independent P300 BCI.
The past decade has witnessed rapid development in the field of brain-computer interfaces (BCIs). While the performance is no longer the biggest bottleneck in the BCI application, the tedious training process and the poor ease-of-use have become the most significant challenges. In this study, a spatio-temporal equalization dynamic window (STE-DW) recognition algorithm is proposed for steady-state visual evoked potential (SSVEP)-based BCIs. The algorithm can adaptively control the stimulus time while maintaining the recognition accuracy, which significantly improves the information transfer rate (ITR) and enhances the adaptability of the system to different subjects. Specifically, a spatio-temporal equalization algorithm is used to reduce the adverse effects of spatial and temporal correlation of background noise. Based on the theory of multiple hypotheses testing, a stimulus termination criterion is used to adaptively control the dynamic window. The offline analysis which used a benchmark dataset and an offline dataset collected from 16 subjects demonstrated that the STE-DW algorithm is superior to the filter bank canonical correlation analysis (FBCCA), canonical variates with autoregressive spectral analysis (CVARS), canonical correlation analysis (CCA) and CCA reducing variation (CCA-RV) algorithms in terms of accuracy and ITR. The results show that in the benchmark dataset, the STE-DW algorithm achieved an average ITR of 134 bits/min, which exceeds the FBCCA, CVARS, CCA and CCA-RV. In off-line experiments, the STE-DW algorithm also achieved an average ITR of 116 bits/min. In addition, the online experiment also showed that the STE-DW algorithm can effectively expand the number of applicable users of the SSVEP-based BCI system. We suggest that the STE-DW algorithm can be used as a reliable identification algorithm for training-free SSVEP-based BCIs, because of the good balance between ease of use, recognition accuracy, ITR and user applicability.
Brain-computer interfaces (BCIs) represent a new frontier in the effort to maximize the ability of individuals with profound motor impairments to interact and communicate. While much literature points to BCIs' promise as an alternative access pathway, there have historically been few applications involving children and young adults with severe physical disabilities. As research is emerging in this sphere, this article aims to evaluate the current state of translating BCIs to the pediatric population. A systematic review was conducted using the Scopus, PubMed, and Ovid Medline databases. Studies of children and adolescents that reported BCI performance published in English in peer-reviewed journals between 2008 and May 2020 were included. Twelve publications were identified, providing strong evidence for continued research in pediatric BCIs. Research evidence was generally at multiple case study or exploratory study level, with modest sample sizes. Seven studies focused on BCIs for communication and five on mobility. Articles were categorized and grouped based on type of measurement (i.e., non-invasive and invasive), and the type of brain signal (i.e., sensory evoked potentials or movement-related potentials). Strengths and limitations of studies were identified and used to provide requirements for clinical translation of pediatric BCIs. This systematic review presents the state-of-the-art of pediatric BCIs focused on developing advanced technology to support children and youth with communication disabilities or limited manual ability. Despite a few research studies addressing the application of BCIs for communication and mobility in children, results are encouraging and future works should focus on customizable pediatric access technologies based on brain activity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.